Skip to main content
MOD 8000TL3-X vs Fronius Primo 8.2-1 5 of 21 identical Swap Change inverters

Growatt MOD 8000TL3-X vs Fronius Primo 8.2-1

Growatt MOD 8000TL3-X
Growatt
MOD 8000TL3-X
8 kW 98.1 % euro Grid-tie
VS
Fronius Primo 8.2-1
Fronius International
Fronius Primo 8.2-1
8.2 kW Grid-tie
The verdict

16 differences, and they point both ways

The largest is rated ac power: 0.20 kW apart. 5 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.

See all 16 differences
How alike are they
5 of 21 comparable
parameters are identical
identical differs not published
01

What actually differs

16 of 21 parameters
Parameter MOD 8000TL3-X Fronius Primo 8.2-1 Difference
Rated AC power 8.00 kW 8.20 kW 0.20 kW apart
Warranty 5 yrs 10 yrs 5 yrs longer
Max DC voltage 1100 V 1000 V 100 V apart
Max input current per tracker 13.0 A 33.0 A 20.0 A more headroom
Max efficiency 98.6 % 97.0 % 1.6 pp more efficient
Weight 14.0 kg 21.4 kg 7.4 kg lighter
Weight per kW 1.8 kg/kW 2.6 kg/kW 0.9 kg/kW lighter
Max AC power 8.00 kW 8.20 kW 0.20 kW apart
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 240 V 160 V apart
Max AC current 13.3 A 34.2 A 20.9 A apart
Start voltage 160 V 80 V 80 V earlier start
Ingress protection IP66 NEMA 4X IP66 vs NEMA 4X
MPPT voltage range 140-1000 V 200-800 V 140-1000 V vs 200-800 V
Dimensions 387x425x178 mm 627x429x206 mm 387x425x178 mm vs 627x429x206 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter MOD 8000TL3-X Fronius Primo 8.2-1 Difference
AC output
Rated AC power 8.00 kW 8.20 kW 0.20 kW apart
Max AC power 8.00 kW 8.20 kW 0.20 kW apart
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 240 V 160 V apart
Max AC current 13.3 A 34.2 A 20.9 A apart
PV input
Max PV power 12.00 kW - Not published by Fronius International
DC/AC ratio 1.50 - Not published by Fronius International
Max DC voltage 1100 V 1000 V 100 V apart
MPPT voltage range 140-1000 V 200-800 V 140-1000 V vs 200-800 V
Start voltage 160 V 80 V -80 V for Fronius Primo 8.2-1
MPP trackers 2 2 Same
Strings per tracker 1 - Not published by Fronius International
Max input current per tracker 13.0 A 33.0 A +20.0 A for Fronius Primo 8.2-1
Efficiency
European efficiency 98.1 % - Not published by Fronius International
Max efficiency 98.6 % 97.0 % +1.6 pp for MOD 8000TL3-X
CEC efficiency - 96.5 % Not published by Growatt
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 14.0 kg 21.4 kg -7.4 kg for MOD 8000TL3-X
Weight per kW 1.8 kg/kW 2.6 kg/kW -0.9 kg/kW for MOD 8000TL3-X
Dimensions 387x425x178 mm 627x429x206 mm 387x425x178 mm vs 627x429x206 mm
Ingress protection IP66 NEMA 4X IP66 vs NEMA 4X
Cooling natural forced-air natural vs forced-air
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection - Yes Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs 10 yrs +5 yrs for Fronius Primo 8.2-1
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt MOD 8000TL3-X vs Growatt MOD 8KTL3-X2(Pro)
3 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MOD 8000TL3-X vs Sungrow SG8.0RT-20
8 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Growatt MOD 8000TL3-X vs GoodWe GW8000-DT
9 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.