Growatt MOD 6000TL3-HU vs Sungrow SH6.0RT
VS
The verdict
MOD 6000TL3-HU leads on the differences that matter
The largest is max ac power: 8.40 kW apart. 12 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.
See all 11 differencesHow alike are they
12
of 23 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
11 of 23 parameters
What actually differs
Parameter
MOD 6000TL3-HU
SH6.0RT
Difference
Max AC power
6.60 kW
15.00 kW
8.40 kW apart
Max PV power
12.00 kW
9.00 kW
3.00 kW apart
DC/AC ratio
2.00
1.50
0.50 more oversizing headroom
Max charge current
25 A
30 A
5 A faster charging
Weight
19.0 kg
27.0 kg
8.0 kg lighter
Weight per kW
3.2 kg/kW
4.5 kg/kW
1.3 kg/kW lighter
European efficiency
97.8 %
97.5 %
0.3 pp more efficient
Ingress protection
IP66
IP65
IP66 vs IP65
Battery voltage
600-980 V
150 V - 600 V
600-980 V vs 150 V - 600 V
Max AC current
10.0 A
9.1 A
0.9 A apart
Dimensions
468x408x202 mm
540x460x170 mm
468x408x202 mm vs 540x460x170 mm
02
Full specification
Parameter
MOD 6000TL3-HU
SH6.0RT
Difference
AC output
Rated AC power
6.00 kW
6.00 kW
Same
Max AC power
6.60 kW
15.00 kW
8.40 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
10.0 A
9.1 A
0.9 A apart
PV input
Max PV power
12.00 kW
9.00 kW
3.00 kW apart
DC/AC ratio
2.00
1.50
+0.50 for MOD 6000TL3-HU
Max DC voltage
1000 V
1000 V
Same
MPPT voltage range
140-1000 V
-
Not published by Sungrow
Start voltage
180 V
-
Not published by Sungrow
MPP trackers
2
2
Same
Strings per tracker
1
-
Not published by Sungrow
Max input current per tracker
20.0 A
-
Not published by Sungrow
Efficiency
European efficiency
97.8 %
97.5 %
+0.3 pp for MOD 6000TL3-HU
Max efficiency
98.3 %
98.2 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-980 V
150 V - 600 V
600-980 V vs 150 V - 600 V
Max charge current
25 A
30 A
+5 A for SH6.0RT
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
19.0 kg
27.0 kg
-8.0 kg for MOD 6000TL3-HU
Weight per kW
3.2 kg/kW
4.5 kg/kW
-1.3 kg/kW for MOD 6000TL3-HU
Dimensions
468x408x202 mm
540x460x170 mm
468x408x202 mm vs 540x460x170 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
29 dB
30 dB
Effectively the same
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
Yes
-
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
10 yrs
-
Not published by Sungrow
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt MOD 6000TL3-HU vs SolarEdge SE6000H
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 6000TL3-HU vs Huawei SUN2000-6KTL-L1
16 differences, the largest is max dc voltage
Same type, similar size
Huawei
Growatt MOD 6000TL3-HU vs Huawei SUN2000-6KTL-M1
13 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.