Growatt MOD 6000TL3-HU
Growatt
MOD 6000TL3-HU
6 kW 97.8 % euro Hybrid
VS
SMA Solar SBSE6.0-50
SMA Solar
SBSE6.0-50
6 kW 97.5 % euro Hybrid
The verdict

MOD 6000TL3-HU leads on the differences that matter

The largest is warranty: 5 yrs longer. 10 of 29 comparable parameters are identical, with 3 more left out because at least one datasheet does not publish them.

See all 19 differences
How alike are they
10 of 29 comparable
parameters are identical
identical differs not published
01

What actually differs

19 of 29 parameters
Parameter MOD 6000TL3-HU SBSE6.0-50 Difference
Warranty 10 yrs 5 yrs 5 yrs longer
Max DC voltage 1000 V 600 V 400 V apart
Max input current per tracker 20.0 A 15.0 A 5.0 A more headroom
Max AC power 6.60 kW 6.00 kW 0.60 kW apart
Max charge current 25 A 30 A 5 A faster charging
European efficiency 97.8 % 97.5 % 0.3 pp more efficient
Weight 19.0 kg 17.5 kg 1.5 kg lighter
Noise 29 dB 35 dB 6 dB quieter
Max efficiency 98.3 % 98.0 % 0.3 pp more efficient
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 10.0 A 30.0 A 20.0 A apart
Start voltage 180 V 66 V 114 V earlier start
MPP trackers 2 3 1 tracker more
Ingress protection IP66 IP65 IP66 vs IP65
Weight per kW 3.2 kg/kW 2.9 kg/kW 0.2 kg/kW lighter
MPPT voltage range 140-1000 V 60-480 V 140-1000 V vs 60-480 V
Battery voltage 600-980 V 90 V to 500 V 600-980 V vs 90 V to 500 V
Dimensions 468x408x202 mm 586x500x236 mm 468x408x202 mm vs 586x500x236 mm
02

Full specification

Parameter MOD 6000TL3-HU SBSE6.0-50 Difference
AC output
Rated AC power 6.00 kW 6.00 kW Same
Max AC power 6.60 kW 6.00 kW 0.60 kW apart
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 10.0 A 30.0 A 20.0 A apart
PV input
Max PV power 12.00 kW 12.00 kW Same
DC/AC ratio 2.00 2.00 Same
Max DC voltage 1000 V 600 V 400 V apart
MPPT voltage range 140-1000 V 60-480 V 140-1000 V vs 60-480 V
Start voltage 180 V 66 V -114 V for SBSE6.0-50
MPP trackers 2 3 +1 trackers for SBSE6.0-50
Strings per tracker 1 1 Same
Max input current per tracker 20.0 A 15.0 A +5.0 A for MOD 6000TL3-HU
Efficiency
European efficiency 97.8 % 97.5 % +0.3 pp for MOD 6000TL3-HU
Max efficiency 98.3 % 98.0 % +0.3 pp for MOD 6000TL3-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-980 V 90 V to 500 V 600-980 V vs 90 V to 500 V
Max charge current 25 A 30 A +5 A for SBSE6.0-50
Backup power - 7.3 kW Not published by Growatt
Physical
Weight 19.0 kg 17.5 kg -1.5 kg for SBSE6.0-50
Weight per kW 3.2 kg/kW 2.9 kg/kW -0.2 kg/kW for SBSE6.0-50
Dimensions 468x408x202 mm 586x500x236 mm 468x408x202 mm vs 586x500x236 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise 29 dB 35 dB -6 dB for MOD 6000TL3-HU
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Growatt
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty 10 yrs 5 yrs +5 yrs for MOD 6000TL3-HU
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MOD 6000TL3-HU vs SolarEdge SE6000H
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 6000TL3-HU vs Huawei SUN2000-6KTL-L1
16 differences, the largest is max dc voltage
Same type, similar size
Huawei
Growatt MOD 6000TL3-HU vs Huawei SUN2000-6KTL-M1
13 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.