Growatt MOD 6000TL3-HU vs SMA Solar SBSE6.0-50
VS
The verdict
MOD 6000TL3-HU leads on the differences that matter
The largest is warranty: 5 yrs longer. 10 of 29 comparable parameters are identical, with 3 more left out because at least one datasheet does not publish them.
See all 19 differencesHow alike are they
10
of 29 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
19 of 29 parameters
What actually differs
Parameter
MOD 6000TL3-HU
SBSE6.0-50
Difference
Warranty
10 yrs
5 yrs
5 yrs longer
Max DC voltage
1000 V
600 V
400 V apart
Max input current per tracker
20.0 A
15.0 A
5.0 A more headroom
Max AC power
6.60 kW
6.00 kW
0.60 kW apart
Max charge current
25 A
30 A
5 A faster charging
European efficiency
97.8 %
97.5 %
0.3 pp more efficient
Weight
19.0 kg
17.5 kg
1.5 kg lighter
Noise
29 dB
35 dB
6 dB quieter
Max efficiency
98.3 %
98.0 %
0.3 pp more efficient
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
10.0 A
30.0 A
20.0 A apart
Start voltage
180 V
66 V
114 V earlier start
MPP trackers
2
3
1 tracker more
Ingress protection
IP66
IP65
IP66 vs IP65
Weight per kW
3.2 kg/kW
2.9 kg/kW
0.2 kg/kW lighter
MPPT voltage range
140-1000 V
60-480 V
140-1000 V vs 60-480 V
Battery voltage
600-980 V
90 V to 500 V
600-980 V vs 90 V to 500 V
Dimensions
468x408x202 mm
586x500x236 mm
468x408x202 mm vs 586x500x236 mm
02
Full specification
Parameter
MOD 6000TL3-HU
SBSE6.0-50
Difference
AC output
Rated AC power
6.00 kW
6.00 kW
Same
Max AC power
6.60 kW
6.00 kW
0.60 kW apart
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
10.0 A
30.0 A
20.0 A apart
PV input
Max PV power
12.00 kW
12.00 kW
Same
DC/AC ratio
2.00
2.00
Same
Max DC voltage
1000 V
600 V
400 V apart
MPPT voltage range
140-1000 V
60-480 V
140-1000 V vs 60-480 V
Start voltage
180 V
66 V
-114 V for SBSE6.0-50
MPP trackers
2
3
+1 trackers for SBSE6.0-50
Strings per tracker
1
1
Same
Max input current per tracker
20.0 A
15.0 A
+5.0 A for MOD 6000TL3-HU
Efficiency
European efficiency
97.8 %
97.5 %
+0.3 pp for MOD 6000TL3-HU
Max efficiency
98.3 %
98.0 %
+0.3 pp for MOD 6000TL3-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-980 V
90 V to 500 V
600-980 V vs 90 V to 500 V
Max charge current
25 A
30 A
+5 A for SBSE6.0-50
Backup power
-
7.3 kW
Not published by Growatt
Physical
Weight
19.0 kg
17.5 kg
-1.5 kg for SBSE6.0-50
Weight per kW
3.2 kg/kW
2.9 kg/kW
-0.2 kg/kW for SBSE6.0-50
Dimensions
468x408x202 mm
586x500x236 mm
468x408x202 mm vs 586x500x236 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
29 dB
35 dB
-6 dB for MOD 6000TL3-HU
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
10 yrs
5 yrs
+5 yrs for MOD 6000TL3-HU
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt MOD 6000TL3-HU vs SolarEdge SE6000H
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 6000TL3-HU vs Huawei SUN2000-6KTL-L1
16 differences, the largest is max dc voltage
Same type, similar size
Huawei
Growatt MOD 6000TL3-HU vs Huawei SUN2000-6KTL-M1
13 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.