Skip to main content
MOD 6000TL3-HU vs SUN-6K-SG03LP1-EU 9 of 27 identical Swap Change inverters

Growatt MOD 6000TL3-HU vs Deye SUN-6K-SG03LP1-EU

Growatt MOD 6000TL3-HU
Growatt
MOD 6000TL3-HU
6 kW 97.8 % euro Hybrid
VS
Deye
SUN-6K-SG03LP1-EU
6 kW 96.5 % euro Hybrid
The verdict

MOD 6000TL3-HU leads on the differences that matter

The largest is european efficiency: 1.3 pp more efficient. 9 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.

See all 18 differences
How alike are they
9 of 27 comparable
parameters are identical
identical differs not published
01

What actually differs

18 of 27 parameters
Parameter MOD 6000TL3-HU SUN-6K-SG03LP1-EU Difference
European efficiency 97.8 % 96.5 % 1.3 pp more efficient
Warranty 10 yrs 5 yrs 5 yrs longer
Max DC voltage 1000 V 500 V 500 V apart
Max input current per tracker 20.0 A 13.0 A 7.0 A more headroom
Max efficiency 98.3 % 97.6 % 0.7 pp more efficient
Max PV power 12.00 kW 7.80 kW 4.20 kW apart
DC/AC ratio 2.00 1.30 0.70 more oversizing headroom
Weight 19.0 kg 25.0 kg 6.0 kg lighter
Weight per kW 3.2 kg/kW 4.2 kg/kW 1.0 kg/kW lighter
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 10.0 A 30.0 A 20.0 A apart
Start voltage 180 V 125 V 55 V earlier start
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 140-1000 V 150-425 V 140-1000 V vs 150-425 V
Battery voltage 600-980 V 40-60 600-980 V vs 40-60
Dimensions 468x408x202 mm 580x330x232 mm 468x408x202 mm vs 580x330x232 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter MOD 6000TL3-HU SUN-6K-SG03LP1-EU Difference
AC output
Rated AC power 6.00 kW 6.00 kW Same
Max AC power 6.60 kW 6.60 kW Same
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 10.0 A 30.0 A 20.0 A apart
PV input
Max PV power 12.00 kW 7.80 kW 4.20 kW apart
DC/AC ratio 2.00 1.30 +0.70 for MOD 6000TL3-HU
Max DC voltage 1000 V 500 V 500 V apart
MPPT voltage range 140-1000 V 150-425 V 140-1000 V vs 150-425 V
Start voltage 180 V 125 V -55 V for SUN-6K-SG03LP1-EU
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 20.0 A 13.0 A +7.0 A for MOD 6000TL3-HU
Efficiency
European efficiency 97.8 % 96.5 % +1.3 pp for MOD 6000TL3-HU
Max efficiency 98.3 % 97.6 % +0.7 pp for MOD 6000TL3-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-980 V 40-60 600-980 V vs 40-60
Max charge current 25 A - Not published by Deye
Backup power - - Neither datasheet publishes this
Physical
Weight 19.0 kg 25.0 kg -6.0 kg for MOD 6000TL3-HU
Weight per kW 3.2 kg/kW 4.2 kg/kW -1.0 kg/kW for MOD 6000TL3-HU
Dimensions 468x408x202 mm 580x330x232 mm 468x408x202 mm vs 580x330x232 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural forced-air natural vs forced-air
Noise 29 dB 30 dB Effectively the same
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes - Not published by Deye
Integrated DC switch Yes Yes Same
Warranty
Warranty 10 yrs 5 yrs +5 yrs for MOD 6000TL3-HU
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MOD 6000TL3-HU vs SolarEdge SE6000H
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 6000TL3-HU vs Huawei SUN2000-6KTL-L1