Skip to main content
MOD 5000TL3-HU vs Fronius Primo GEN24 5.0 7 of 27 identical Swap Change inverters

Growatt MOD 5000TL3-HU vs Fronius Primo GEN24 5.0

Growatt MOD 5000TL3-HU
Growatt
MOD 5000TL3-HU
5 kW 97.8 % euro Hybrid
VS
Fronius International
Fronius Primo GEN24 5.0
5 kW 97.2 % euro Hybrid
The verdict

MOD 5000TL3-HU leads on the differences that matter

The largest is european efficiency: 0.6 pp more efficient. 7 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.

See all 20 differences
How alike are they
7 of 27 comparable
parameters are identical
identical differs not published
01

What actually differs

20 of 27 parameters
Parameter MOD 5000TL3-HU Fronius Primo GEN24 5.0 Difference
European efficiency 97.8 % 97.2 % 0.6 pp more efficient
Max DC voltage 1000 V 600 V 400 V apart
Max input current per tracker 20.0 A 22.0 A 2.0 A more headroom
Max efficiency 98.3 % 97.6 % 0.7 pp more efficient
Max AC power 5.50 kW 5.00 kW 0.50 kW apart
Max PV power 10.00 kW 5.17 kW 4.83 kW apart
DC/AC ratio 2.00 1.03 0.97 more oversizing headroom
Weight 19.0 kg 15.4 kg 3.6 kg lighter
Noise 29 dB 42 dB 13 dB quieter
Weight per kW 3.8 kg/kW 3.1 kg/kW 0.7 kg/kW lighter
Max charge current 25 A 22 A 3 A faster charging
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 8.3 A 22.7 A 14.4 A apart
Start voltage 180 V 80 V 100 V earlier start
MPPT voltage range 140-1000 V 65-530 V 140-1000 V vs 65-530 V
Battery voltage 600-980 V 150-455 V 600-980 V vs 150-455 V
Strings per tracker 1 2 1 string apart
Dimensions 468x408x202 mm 530x474x165 mm 468x408x202 mm vs 530x474x165 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter MOD 5000TL3-HU Fronius Primo GEN24 5.0 Difference
AC output
Rated AC power 5.00 kW 5.00 kW Same
Max AC power 5.50 kW 5.00 kW 0.50 kW apart
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 8.3 A 22.7 A 14.4 A apart
PV input
Max PV power 10.00 kW 5.17 kW 4.83 kW apart
DC/AC ratio 2.00 1.03 +0.97 for MOD 5000TL3-HU
Max DC voltage 1000 V 600 V 400 V apart
MPPT voltage range 140-1000 V 65-530 V 140-1000 V vs 65-530 V
Start voltage 180 V 80 V -100 V for Fronius Primo GEN24 5.0
MPP trackers 2 2 Same
Strings per tracker 1 2 1 string apart
Max input current per tracker 20.0 A 22.0 A +2.0 A for Fronius Primo GEN24 5.0
Efficiency
European efficiency 97.8 % 97.2 % +0.6 pp for MOD 5000TL3-HU
Max efficiency 98.3 % 97.6 % +0.7 pp for MOD 5000TL3-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-980 V 150-455 V 600-980 V vs 150-455 V
Max charge current 25 A 22 A +3 A for MOD 5000TL3-HU
Backup power - - Neither datasheet publishes this
Physical
Weight 19.0 kg 15.4 kg -3.6 kg for Fronius Primo GEN24 5.0
Weight per kW 3.8 kg/kW 3.1 kg/kW -0.7 kg/kW for Fronius Primo GEN24 5.0
Dimensions 468x408x202 mm 530x474x165 mm 468x408x202 mm vs 530x474x165 mm
Ingress protection IP66 IP66 Same
Cooling natural forced-air natural vs forced-air
Noise 29 dB 42 dB -13 dB for MOD 5000TL3-HU
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Growatt
Arc fault protection Yes - Not published by Fronius International
Integrated DC switch Yes Yes Same
Warranty
Warranty 10 yrs - Not published by Fronius International
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MOD 5000TL3-HU vs SolarEdge StorEdge AC Coupled Single Phase Inverter (HD‑Wave) - SE5000H / H5000SE
13 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Growatt MOD 5000TL3-HU vs SolarEdge SE5000H
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 5000TL3-HU vs Huawei SUN2000L-5KTL
15 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.