Growatt MOD 4000TL3-XH vs Growatt SPM 4000TL-HU
VS
The verdict
MOD 4000TL3-XH leads on the differences that matter
The largest is max dc voltage: 500 V apart. 10 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.
See all 16 differencesHow alike are they
10
of 26 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
16 of 26 parameters
What actually differs
Parameter
MOD 4000TL3-XH
SPM 4000TL-HU
Difference
Max DC voltage
1100 V
600 V
500 V apart
Max input current per tracker
16.0 A
22.0 A
6.0 A more headroom
Max AC power
4.40 kW
4.00 kW
0.40 kW apart
Max PV power
8.00 kW
6.00 kW
2.00 kW apart
DC/AC ratio
2.00
1.50
0.50 more oversizing headroom
Weight
12.5 kg
26.0 kg
13.5 kg lighter
Weight per kW
3.1 kg/kW
6.5 kg/kW
3.4 kg/kW lighter
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
6.7 A
17.4 A
10.7 A apart
Max efficiency
98.3 %
98.1 %
0.2 pp more efficient
Start voltage
160 V
130 V
30 V earlier start
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
140-1000 V
150-550 V
140-1000 V vs 150-550 V
Battery voltage
600-950 V
40-60V
600-950 V vs 40-60V
Dimensions
387x425x147 mm
330x580x230 mm
387x425x147 mm vs 330x580x230 mm
02
Full specification
Parameter
MOD 4000TL3-XH
SPM 4000TL-HU
Difference
AC output
Rated AC power
4.00 kW
4.00 kW
Same
Max AC power
4.40 kW
4.00 kW
0.40 kW apart
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
6.7 A
17.4 A
10.7 A apart
PV input
Max PV power
8.00 kW
6.00 kW
2.00 kW apart
DC/AC ratio
2.00
1.50
+0.50 for MOD 4000TL3-XH
Max DC voltage
1100 V
600 V
500 V apart
MPPT voltage range
140-1000 V
150-550 V
140-1000 V vs 150-550 V
Start voltage
160 V
130 V
-30 V for SPM 4000TL-HU
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
16.0 A
22.0 A
+6.0 A for SPM 4000TL-HU
Efficiency
European efficiency
97.5 %
97.6 %
Effectively the same
Max efficiency
98.3 %
98.1 %
+0.2 pp for MOD 4000TL3-XH
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-950 V
40-60V
600-950 V vs 40-60V
Max charge current
-
140 A
Not published by Growatt
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
12.5 kg
26.0 kg
-13.5 kg for MOD 4000TL3-XH
Weight per kW
3.1 kg/kW
6.5 kg/kW
-3.4 kg/kW for MOD 4000TL3-XH
Dimensions
387x425x147 mm
330x580x230 mm
387x425x147 mm vs 330x580x230 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
-
30 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
-
Not published by Growatt
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt MOD 4000TL3-XH vs SolarEdge SE4000H
10 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 4000TL3-XH vs Huawei SUN2000L-4KTL
14 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MOD 4000TL3-XH vs Growatt MOD 4000TL3-HU
9 differences, the largest is warranty
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.