Growatt MOD 4000TL3-HU vs SolarEdge SE7K (Three Phase, Delta Grids)
VS
The verdict
MOD 4000TL3-HU leads on the differences that matter
The largest is european efficiency: 0.5 pp more efficient. 5 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
5
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 19 parameters
What actually differs
Parameter
MOD 4000TL3-HU
SE7K (Three Phase, Delta Grids)
Difference
European efficiency
97.8 %
97.3 %
0.5 pp more efficient
Max DC voltage
1000 V
600 V
400 V apart
Max AC power
4.40 kW
4.00 kW
0.40 kW apart
Max PV power
8.00 kW
5.40 kW
2.60 kW apart
DC/AC ratio
2.00
1.35
0.65 more oversizing headroom
Weight
19.0 kg
16.4 kg
2.6 kg lighter
Noise
29 dB
50 dB
21 dB quieter
Weight per kW
4.8 kg/kW
4.1 kg/kW
0.7 kg/kW lighter
Max efficiency
98.3 %
98.0 %
0.3 pp more efficient
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
6.7 A
11.5 A
4.8 A apart
Ingress protection
IP66
IP65
IP66 vs IP65
Dimensions
468x408x202 mm
540x315x260 mm
468x408x202 mm vs 540x315x260 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
MOD 4000TL3-HU
SE7K (Three Phase, Delta Grids)
Difference
AC output
Rated AC power
4.00 kW
4.00 kW
Same
Max AC power
4.40 kW
4.00 kW
0.40 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
6.7 A
11.5 A
4.8 A apart
PV input
Max PV power
8.00 kW
5.40 kW
2.60 kW apart
DC/AC ratio
2.00
1.35
+0.65 for MOD 4000TL3-HU
Max DC voltage
1000 V
600 V
400 V apart
MPPT voltage range
140-1000 V
-
Not published by SolarEdge
Start voltage
180 V
-
Not published by SolarEdge
MPP trackers
2
-
Not published by SolarEdge
Strings per tracker
1
-
Not published by SolarEdge
Max input current per tracker
20.0 A
-
Not published by SolarEdge
Efficiency
European efficiency
97.8 %
97.3 %
+0.5 pp for MOD 4000TL3-HU
Max efficiency
98.3 %
98.0 %
+0.3 pp for MOD 4000TL3-HU
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-980 V
-
Not published by SolarEdge
Max charge current
25 A
-
Not published by SolarEdge
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
19.0 kg
16.4 kg
-2.6 kg for SE7K (Three Phase, Delta Grids)
Weight per kW
4.8 kg/kW
4.1 kg/kW
-0.7 kg/kW for SE7K (Three Phase, Delta Grids)
Dimensions
468x408x202 mm
540x315x260 mm
468x408x202 mm vs 540x315x260 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
forced-air
natural vs forced-air
Noise
29 dB
50 dB
-21 dB for MOD 4000TL3-HU
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
Yes
-
Not published by SolarEdge
Integrated DC switch
Yes
-
Not published by SolarEdge
Warranty
Warranty
10 yrs
-
Not published by SolarEdge
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt MOD 4000TL3-HU vs SolarEdge SE4000H
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 4000TL3-HU vs Huawei SUN2000L-4KTL
14 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MOD 4000TL3-HU vs Growatt SPM 4000TL-HU
19 differences, the largest is warranty
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.