Skip to main content
MOD 3000TL3-XH vs SPM 3000TL-HU 10 of 26 identical Swap Change inverters

Growatt MOD 3000TL3-XH vs Growatt SPM 3000TL-HU

Growatt MOD 3000TL3-XH
Growatt
MOD 3000TL3-XH
3 kW 97.5 % euro Hybrid
VS
Growatt SPM 3000TL-HU
Growatt
SPM 3000TL-HU
3 kW 97.6 % euro Hybrid
The verdict

MOD 3000TL3-XH leads on the differences that matter

The largest is max dc voltage: 500 V apart. 10 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.

See all 16 differences
How alike are they
10 of 26 comparable
parameters are identical
identical differs not published
01

What actually differs

16 of 26 parameters
Parameter MOD 3000TL3-XH SPM 3000TL-HU Difference
Max DC voltage 1100 V 600 V 500 V apart
Max input current per tracker 16.0 A 22.0 A 6.0 A more headroom
Max AC power 3.30 kW 3.00 kW 0.30 kW apart
Max PV power 6.00 kW 4.50 kW 1.50 kW apart
DC/AC ratio 2.00 1.50 0.50 more oversizing headroom
Weight 12.5 kg 26.0 kg 13.5 kg lighter
Weight per kW 4.2 kg/kW 8.7 kg/kW 4.5 kg/kW lighter
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 5.0 A 13.1 A 8.1 A apart
Max efficiency 98.3 % 98.1 % 0.2 pp more efficient
Start voltage 160 V 130 V 30 V earlier start
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 140-1000 V 150-550 V 140-1000 V vs 150-550 V
Battery voltage 600-950 V 40-60V 600-950 V vs 40-60V
Dimensions 387x425x147 mm 330x580x230 mm 387x425x147 mm vs 330x580x230 mm
02

Full specification

Parameter MOD 3000TL3-XH SPM 3000TL-HU Difference
AC output
Rated AC power 3.00 kW 3.00 kW Same
Max AC power 3.30 kW 3.00 kW 0.30 kW apart
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 5.0 A 13.1 A 8.1 A apart
PV input
Max PV power 6.00 kW 4.50 kW 1.50 kW apart
DC/AC ratio 2.00 1.50 +0.50 for MOD 3000TL3-XH
Max DC voltage 1100 V 600 V 500 V apart
MPPT voltage range 140-1000 V 150-550 V 140-1000 V vs 150-550 V
Start voltage 160 V 130 V -30 V for SPM 3000TL-HU
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 16.0 A 22.0 A +6.0 A for SPM 3000TL-HU
Efficiency
European efficiency 97.5 % 97.6 % Effectively the same
Max efficiency 98.3 % 98.1 % +0.2 pp for MOD 3000TL3-XH
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-950 V 40-60V 600-950 V vs 40-60V
Max charge current - 140 A Not published by Growatt
Backup power - - Neither datasheet publishes this
Physical
Weight 12.5 kg 26.0 kg -13.5 kg for MOD 3000TL3-XH
Weight per kW 4.2 kg/kW 8.7 kg/kW -4.5 kg/kW for MOD 3000TL3-XH
Dimensions 387x425x147 mm 330x580x230 mm 387x425x147 mm vs 330x580x230 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise - 30 dB Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes - Not published by Growatt
Warranty
Warranty 5 yrs 5 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MOD 3000TL3-XH vs SolarEdge SE3000H
10 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 3000TL3-XH vs Growatt MOD 3000TL3-HU
9 differences, the largest is warranty
Same type, similar size
Huawei
Growatt MOD 3000TL3-XH vs Huawei SUN2000L-3KTL
13 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.