Skip to main content
MOD 3000TL3-X vs MIN 3000TL-X 9 of 24 identical Swap Change inverters

Growatt MOD 3000TL3-X vs Growatt MIN 3000TL-X

Growatt MOD 3000TL3-X
Growatt
MOD 3000TL3-X
3 kW 97.5 % euro Grid-tie
VS
Growatt MIN 3000TL-X
Growatt
MIN 3000TL-X
3 kW 97.0 % euro Grid-tie
The verdict

15 differences, and they point both ways

The largest is european efficiency: 0.5 pp more efficient. 9 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
9 of 24 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 24 parameters
Parameter MOD 3000TL3-X MIN 3000TL-X Difference
European efficiency 97.5 % 97.0 % 0.5 pp more efficient
Max DC voltage 1100 V 550 V 550 V apart
Max AC power 3.00 kW 3.30 kW 0.30 kW apart
Weight 12.5 kg 10.8 kg 1.7 kg lighter
Max PV power 4.50 kW 4.20 kW 0.30 kW apart
Weight per kW 4.2 kg/kW 3.6 kg/kW 0.6 kg/kW lighter
DC/AC ratio 1.50 1.40 0.10 more oversizing headroom
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 220 V 180 V apart
Max AC current 5.0 A 14.4 A 9.4 A apart
Start voltage 160 V 100 V 60 V earlier start
Max input current per tracker 13.0 A 12.5 A 0.5 A more headroom
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 140-1000 V 80-550 V 140-1000 V vs 80-550 V
Dimensions 387x425x147 mm 350x375x158 mm 387x425x147 mm vs 350x375x158 mm
02

Full specification

Parameter MOD 3000TL3-X MIN 3000TL-X Difference
AC output
Rated AC power 3.00 kW 3.00 kW Same
Max AC power 3.00 kW 3.30 kW 0.30 kW apart
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 220 V 180 V apart
Max AC current 5.0 A 14.4 A 9.4 A apart
PV input
Max PV power 4.50 kW 4.20 kW 0.30 kW apart
DC/AC ratio 1.50 1.40 +0.10 for MOD 3000TL3-X
Max DC voltage 1100 V 550 V 550 V apart
MPPT voltage range 140-1000 V 80-550 V 140-1000 V vs 80-550 V
Start voltage 160 V 100 V -60 V for MIN 3000TL-X
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 13.0 A 12.5 A +0.5 A for MOD 3000TL3-X
Efficiency
European efficiency 97.5 % 97.0 % +0.5 pp for MOD 3000TL3-X
Max efficiency 98.3 % 98.2 % Effectively the same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 12.5 kg 10.8 kg -1.7 kg for MIN 3000TL-X
Weight per kW 4.2 kg/kW 3.6 kg/kW -0.6 kg/kW for MIN 3000TL-X
Dimensions 387x425x147 mm 350x375x158 mm 387x425x147 mm vs 350x375x158 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Growatt
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs 5 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MOD 3000TL3-X vs SolarEdge SE3000H (HD‑Wave, single phase)
13 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MOD 3000TL3-X vs Solis-3P3K-4G
11 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Growatt MOD 3000TL3-X vs Ginlong Solis S6-GR3P-3K02-NV-ND
6 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.