Skip to main content
MOD 3000TL3-X vs MIC 3000TL-X2 11 of 24 identical Swap Change inverters

Growatt MOD 3000TL3-X vs Growatt MIC 3000TL-X2

Growatt MOD 3000TL3-X
Growatt
MOD 3000TL3-X
3 kW 97.5 % euro Grid-tie
VS
Growatt MIC 3000TL-X2
Growatt
MIC 3000TL-X2
3 kW 97.1 % euro Grid-tie
The verdict

13 differences, and they point both ways

The largest is max dc voltage: 550 V apart. 11 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.

See all 13 differences
How alike are they
11 of 24 comparable
parameters are identical
identical differs not published
01

What actually differs

13 of 24 parameters
Parameter MOD 3000TL3-X MIC 3000TL-X2 Difference
Max DC voltage 1100 V 550 V 550 V apart
Max input current per tracker 13.0 A 16.0 A 3.0 A more headroom
Max efficiency 98.3 % 97.6 % 0.7 pp more efficient
European efficiency 97.5 % 97.1 % 0.4 pp more efficient
Weight 12.5 kg 6.2 kg 6.3 kg lighter
Weight per kW 4.2 kg/kW 2.1 kg/kW 2.1 kg/kW lighter
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 5.0 A 14.3 A 9.3 A apart
Start voltage 160 V 50 V 110 V earlier start
MPP trackers 2 1 1 tracker more
MPPT voltage range 140-1000 V 50-550 V 140-1000 V vs 50-550 V
Dimensions 387x425x147 mm 254x274x138 mm 387x425x147 mm vs 254x274x138 mm
02

Full specification

Parameter MOD 3000TL3-X MIC 3000TL-X2 Difference
AC output
Rated AC power 3.00 kW 3.00 kW Same
Max AC power 3.00 kW 3.00 kW Same
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 5.0 A 14.3 A 9.3 A apart
PV input
Max PV power 4.50 kW 4.50 kW Same
DC/AC ratio 1.50 1.50 Same
Max DC voltage 1100 V 550 V 550 V apart
MPPT voltage range 140-1000 V 50-550 V 140-1000 V vs 50-550 V
Start voltage 160 V 50 V -110 V for MIC 3000TL-X2
MPP trackers 2 1 +1 trackers for MOD 3000TL3-X
Strings per tracker 1 1 Same
Max input current per tracker 13.0 A 16.0 A +3.0 A for MIC 3000TL-X2
Efficiency
European efficiency 97.5 % 97.1 % +0.4 pp for MOD 3000TL3-X
Max efficiency 98.3 % 97.6 % +0.7 pp for MOD 3000TL3-X
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 12.5 kg 6.2 kg -6.3 kg for MIC 3000TL-X2
Weight per kW 4.2 kg/kW 2.1 kg/kW -2.1 kg/kW for MIC 3000TL-X2
Dimensions 387x425x147 mm 254x274x138 mm 387x425x147 mm vs 254x274x138 mm
Ingress protection IP66 IP66 Same
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes - Not published by Growatt
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs 5 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MOD 3000TL3-X vs SolarEdge SE3000H (HD‑Wave, single phase)
13 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MOD 3000TL3-X vs Solis-3P3K-4G
11 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Growatt MOD 3000TL3-X vs Ginlong Solis S6-GR3P-3K02-NV-ND
6 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.