Growatt MOD 3000TL3-X
Growatt
MOD 3000TL3-X
3 kW 97.5 % euro Grid-tie
VS
Ginlong Solis S6-GR1P3K-S
Ginlong Solis
S6-GR1P3K-S
3 kW 96.6 % euro Grid-tie
The verdict

12 differences, and they point both ways

The largest is european efficiency: 0.9 pp more efficient. 10 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
10 of 22 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 22 parameters
Parameter MOD 3000TL3-X S6-GR1P3K-S Difference
European efficiency 97.5 % 96.6 % 0.9 pp more efficient
Max DC voltage 1100 V 550 V 550 V apart
Max input current per tracker 13.0 A 16.0 A 3.0 A more headroom
Max efficiency 98.3 % 97.3 % 1.0 pp more efficient
Weight 12.5 kg 8.3 kg 4.2 kg lighter
Weight per kW 4.2 kg/kW 2.8 kg/kW 1.4 kg/kW lighter
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 5.0 A 13.6 A 8.6 A apart
Start voltage 160 V 60 V 100 V earlier start
MPPT voltage range 140-1000 V 50-550 V 140-1000 V vs 50-550 V
Dimensions 387x425x147 mm 371x330x161 mm 387x425x147 mm vs 371x330x161 mm
02

Full specification

Parameter MOD 3000TL3-X S6-GR1P3K-S Difference
AC output
Rated AC power 3.00 kW 3.00 kW Same
Max AC power 3.00 kW 3.00 kW Same
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 5.0 A 13.6 A 8.6 A apart
PV input
Max PV power 4.50 kW 4.50 kW Same
DC/AC ratio 1.50 1.50 Same
Max DC voltage 1100 V 550 V 550 V apart
MPPT voltage range 140-1000 V 50-550 V 140-1000 V vs 50-550 V
Start voltage 160 V 60 V -100 V for S6-GR1P3K-S
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 13.0 A 16.0 A +3.0 A for S6-GR1P3K-S
Efficiency
European efficiency 97.5 % 96.6 % +0.9 pp for MOD 3000TL3-X
Max efficiency 98.3 % 97.3 % +1.0 pp for MOD 3000TL3-X
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 12.5 kg 8.3 kg -4.2 kg for S6-GR1P3K-S
Weight per kW 4.2 kg/kW 2.8 kg/kW -1.4 kg/kW for S6-GR1P3K-S
Dimensions 387x425x147 mm 371x330x161 mm 387x425x147 mm vs 371x330x161 mm
Ingress protection IP66 IP66 Same
Cooling natural natural Same
Noise - 20 dB Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by Ginlong Solis
Ethernet Yes - Not published by Ginlong Solis
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MOD 3000TL3-X vs SolarEdge SE3000H (HD‑Wave, single phase)
13 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MOD 3000TL3-X vs Solis-3P3K-4G
11 differences, the largest is max dc voltage