Growatt MOD 3000TL3-HU vs Growatt MIN 3000TL-XH
VS
The verdict
MOD 3000TL3-HU leads on the differences that matter
The largest is european efficiency: 0.7 pp more efficient. 12 of 28 comparable parameters are identical, with 4 more left out because at least one datasheet does not publish them.
See all 16 differencesHow alike are they
12
of 28 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
16 of 28 parameters
What actually differs
Parameter
MOD 3000TL3-HU
MIN 3000TL-XH
Difference
European efficiency
97.8 %
97.1 %
0.7 pp more efficient
Warranty
10 yrs
5 yrs
5 yrs longer
Max DC voltage
1000 V
550 V
450 V apart
Max input current per tracker
20.0 A
13.5 A
6.5 A more headroom
Max AC power
3.30 kW
3.00 kW
0.30 kW apart
Max charge current
25 A
17 A
8 A faster charging
Weight
19.0 kg
10.8 kg
8.2 kg lighter
Weight per kW
6.3 kg/kW
3.6 kg/kW
2.7 kg/kW lighter
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
5.0 A
13.6 A
8.6 A apart
Start voltage
180 V
100 V
80 V earlier start
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
140-1000 V
70-550 V
140-1000 V vs 70-550 V
Battery voltage
600-980 V
360-550V
600-980 V vs 360-550V
Dimensions
468x408x202 mm
350x375x160 mm
468x408x202 mm vs 350x375x160 mm
02
Full specification
Parameter
MOD 3000TL3-HU
MIN 3000TL-XH
Difference
AC output
Rated AC power
3.00 kW
3.00 kW
Same
Max AC power
3.30 kW
3.00 kW
0.30 kW apart
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
5.0 A
13.6 A
8.6 A apart
PV input
Max PV power
6.00 kW
6.00 kW
Same
DC/AC ratio
2.00
2.00
Same
Max DC voltage
1000 V
550 V
450 V apart
MPPT voltage range
140-1000 V
70-550 V
140-1000 V vs 70-550 V
Start voltage
180 V
100 V
-80 V for MIN 3000TL-XH
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
20.0 A
13.5 A
+6.5 A for MOD 3000TL3-HU
Efficiency
European efficiency
97.8 %
97.1 %
+0.7 pp for MOD 3000TL3-HU
Max efficiency
98.3 %
98.2 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-980 V
360-550V
600-980 V vs 360-550V
Max charge current
25 A
17 A
+8 A for MOD 3000TL3-HU
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
19.0 kg
10.8 kg
-8.2 kg for MIN 3000TL-XH
Weight per kW
6.3 kg/kW
3.6 kg/kW
-2.7 kg/kW for MIN 3000TL-XH
Dimensions
468x408x202 mm
350x375x160 mm
468x408x202 mm vs 350x375x160 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
29 dB
-
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
10 yrs
5 yrs
+5 yrs for MOD 3000TL3-HU
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt MOD 3000TL3-HU vs SolarEdge SE3000H
11 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 3000TL3-HU vs Growatt SPM 3000TL-HU
19 differences, the largest is warranty
Same type, similar size
Huawei
Growatt MOD 3000TL3-HU vs Huawei SUN2000L-3KTL
15 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.