Skip to main content
MOD 3000TL3-HU vs GW3048-EM 6 of 25 identical Swap Change inverters

Growatt MOD 3000TL3-HU vs GoodWe GW3048-EM

Growatt MOD 3000TL3-HU
Growatt
MOD 3000TL3-HU
3 kW 97.8 % euro Hybrid
VS
GoodWe GW3048-EM
GoodWe
GW3048-EM
3 kW 97.0 % euro Hybrid
The verdict

MOD 3000TL3-HU leads on the differences that matter

The largest is european efficiency: 0.8 pp more efficient. 6 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.

See all 19 differences
How alike are they
6 of 25 comparable
parameters are identical
identical differs not published
01

What actually differs

19 of 25 parameters
Parameter MOD 3000TL3-HU GW3048-EM Difference
European efficiency 97.8 % 97.0 % 0.8 pp more efficient
Max DC voltage 1000 V 550 V 450 V apart
Max input current per tracker 20.0 A 11.0 A 9.0 A more headroom
Max efficiency 98.3 % 97.6 % 0.7 pp more efficient
Max AC power 3.30 kW 3.00 kW 0.30 kW apart
Max PV power 6.00 kW 3.90 kW 2.10 kW apart
DC/AC ratio 2.00 1.30 0.70 more oversizing headroom
Max charge current 25 A 50 A 25 A faster charging
Weight 19.0 kg 16.0 kg 3.0 kg lighter
Weight per kW 6.3 kg/kW 5.3 kg/kW 1.0 kg/kW lighter
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 5.0 A 13.6 A 8.6 A apart
Start voltage 180 V 125 V 55 V earlier start
Noise 29 dB 25 dB 4 dB quieter
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 140-1000 V 100-500 V 140-1000 V vs 100-500 V
Battery voltage 600-980 V 40-60 V 600-980 V vs 40-60 V
Dimensions 468x408x202 mm 432x347x175 mm 468x408x202 mm vs 432x347x175 mm
02

Full specification

Parameter MOD 3000TL3-HU GW3048-EM Difference
AC output
Rated AC power 3.00 kW 3.00 kW Same
Max AC power 3.30 kW 3.00 kW 0.30 kW apart
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 5.0 A 13.6 A 8.6 A apart
PV input
Max PV power 6.00 kW 3.90 kW 2.10 kW apart
DC/AC ratio 2.00 1.30 +0.70 for MOD 3000TL3-HU
Max DC voltage 1000 V 550 V 450 V apart
MPPT voltage range 140-1000 V 100-500 V 140-1000 V vs 100-500 V
Start voltage 180 V 125 V -55 V for GW3048-EM
MPP trackers 2 - Not published by GoodWe
Strings per tracker 1 1 Same
Max input current per tracker 20.0 A 11.0 A +9.0 A for MOD 3000TL3-HU
Efficiency
European efficiency 97.8 % 97.0 % +0.8 pp for MOD 3000TL3-HU
Max efficiency 98.3 % 97.6 % +0.7 pp for MOD 3000TL3-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-980 V 40-60 V 600-980 V vs 40-60 V
Max charge current 25 A 50 A +25 A for GW3048-EM
Backup power - 2.3 kW Not published by Growatt
Physical
Weight 19.0 kg 16.0 kg -3.0 kg for GW3048-EM
Weight per kW 6.3 kg/kW 5.3 kg/kW -1.0 kg/kW for GW3048-EM
Dimensions 468x408x202 mm 432x347x175 mm 468x408x202 mm vs 432x347x175 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise 29 dB 25 dB -4 dB for GW3048-EM
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection Yes - Not published by GoodWe
Integrated DC switch Yes - Not published by GoodWe
Warranty
Warranty 10 yrs - Not published by GoodWe
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MOD 3000TL3-HU vs SolarEdge SE3000H
11 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 3000TL3-HU vs Growatt SPM 3000TL-HU
19 differences, the largest is warranty
Same type, similar size
Huawei
Growatt MOD 3000TL3-HU vs Huawei SUN2000L-3KTL
15 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.