MOD 12KTL3-X2(Pro) leads on the differences that matter
The largest is european efficiency: 0.6 pp more efficient. 10 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
10
of 25 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 25 parameters
What actually differs
Parameter
MOD 12KTL3-X2(Pro)
STP 12-50 (Sunny Tripower X 12)
Difference
European efficiency
98.2 %
97.6 %
0.6 pp more efficient
Max DC voltage
1100 V
1000 V
100 V apart
Max input current per tracker
20.0 A
24.0 A
4.0 A more headroom
Warranty
8 yrs
5 yrs
3 yrs longer
Weight
15.6 kg
35.0 kg
19.4 kg lighter
Weight per kW
1.3 kg/kW
2.9 kg/kW
1.6 kg/kW lighter
Max efficiency
98.6 %
98.2 %
0.4 pp more efficient
Nominal AC voltage
400 V
230 V
170 V apart
MPP trackers
2
3
1 tracker more
Ingress protection
IP66
IP65
IP66 vs IP65
Start voltage
160 V
188 V
28 V earlier start
MPPT voltage range
140-1000 V
150-1000 V
140-1000 V vs 150-1000 V
Strings per tracker
1
2
1 string apart
Dimensions
387x425x178 mm
762x728x266 mm
387x425x178 mm vs 762x728x266 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
MOD 12KTL3-X2(Pro)
STP 12-50 (Sunny Tripower X 12)
Difference
AC output
Rated AC power
12.00 kW
12.00 kW
Same
Max AC power
12.00 kW
12.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
20.0 A
20.0 A
Same
PV input
Max PV power
18.00 kW
18.00 kW
Same
DC/AC ratio
1.50
1.50
Same
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
140-1000 V
150-1000 V
140-1000 V vs 150-1000 V
Start voltage
160 V
188 V
-28 V for MOD 12KTL3-X2(Pro)
MPP trackers
2
3
+1 trackers for STP 12-50 (Sunny Tripower X 12)
Strings per tracker
1
2
1 string apart
Max input current per tracker
20.0 A
24.0 A
+4.0 A for STP 12-50 (Sunny Tripower X 12)
Efficiency
European efficiency
98.2 %
97.6 %
+0.6 pp for MOD 12KTL3-X2(Pro)
Max efficiency
98.6 %
98.2 %
+0.4 pp for MOD 12KTL3-X2(Pro)
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
15.6 kg
35.0 kg
-19.4 kg for MOD 12KTL3-X2(Pro)
Weight per kW
1.3 kg/kW
2.9 kg/kW
-1.6 kg/kW for MOD 12KTL3-X2(Pro)
Dimensions
387x425x178 mm
762x728x266 mm
387x425x178 mm vs 762x728x266 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
forced-air
natural vs forced-air
Noise
-
59 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
Yes
Same
Integrated DC switch
-
Yes
Not published by Growatt
Warranty
Warranty
8 yrs
5 yrs
+3 yrs for MOD 12KTL3-X2(Pro)
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MOD 12KTL3-X2(Pro) vs Growatt MOD 12KTL3-X
4 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MOD 12KTL3-X2(Pro) vs Sungrow SG12KTL-M
7 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MOD 12KTL3-X2(Pro) vs Sungrow SG12RT-20
7 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.