Growatt MOD 12KTL3-X2(Pro) vs Solis-3P12K-4G
VS
The verdict
MOD 12KTL3-X2(Pro) leads on the differences that matter
The largest is max dc voltage: 100 V apart. 7 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
7
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 20 parameters
What actually differs
Parameter
MOD 12KTL3-X2(Pro)
Solis-3P12K-4G
Difference
Max DC voltage
1100 V
1000 V
100 V apart
European efficiency
98.2 %
97.8 %
0.4 pp more efficient
Max AC power
12.00 kW
13.20 kW
1.20 kW apart
Max PV power
18.00 kW
14.50 kW
3.50 kW apart
DC/AC ratio
1.50
1.21
0.29 more oversizing headroom
Weight
15.6 kg
18.9 kg
3.3 kg lighter
Max efficiency
98.6 %
98.3 %
0.3 pp more efficient
Ingress protection
IP66
IP65
IP66 vs IP65
Weight per kW
1.3 kg/kW
1.6 kg/kW
0.3 kg/kW lighter
MPPT voltage range
140-1000 V
160-850 V
140-1000 V vs 160-850 V
Start voltage
160 V
180 V
20 V earlier start
Max AC current
20.0 A
19.1 A
0.9 A apart
Dimensions
387x425x178 mm
563x310x219 mm
387x425x178 mm vs 563x310x219 mm
02
Full specification
Parameter
MOD 12KTL3-X2(Pro)
Solis-3P12K-4G
Difference
AC output
Rated AC power
12.00 kW
12.00 kW
Same
Max AC power
12.00 kW
13.20 kW
1.20 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
20.0 A
19.1 A
0.9 A apart
PV input
Max PV power
18.00 kW
14.50 kW
3.50 kW apart
DC/AC ratio
1.50
1.21
+0.29 for MOD 12KTL3-X2(Pro)
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
140-1000 V
160-850 V
140-1000 V vs 160-850 V
Start voltage
160 V
180 V
-20 V for MOD 12KTL3-X2(Pro)
MPP trackers
2
2
Same
Strings per tracker
1
-
Not published by Ginlong Solis
Max input current per tracker
20.0 A
-
Not published by Ginlong Solis
Efficiency
European efficiency
98.2 %
97.8 %
+0.4 pp for MOD 12KTL3-X2(Pro)
Max efficiency
98.6 %
98.3 %
+0.3 pp for MOD 12KTL3-X2(Pro)
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
15.6 kg
18.9 kg
-3.3 kg for MOD 12KTL3-X2(Pro)
Weight per kW
1.3 kg/kW
1.6 kg/kW
-0.3 kg/kW for MOD 12KTL3-X2(Pro)
Dimensions
387x425x178 mm
563x310x219 mm
387x425x178 mm vs 563x310x219 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
-
Not published by Ginlong Solis
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Ginlong Solis
Arc fault protection
Yes
Yes
Same
Integrated DC switch
-
Yes
Not published by Growatt
Warranty
Warranty
8 yrs
-
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MOD 12KTL3-X2(Pro) vs Growatt MOD 12KTL3-X
4 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MOD 12KTL3-X2(Pro) vs Sungrow SG12KTL-M
7 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MOD 12KTL3-X2(Pro) vs Sungrow SG12RT-20
7 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.