Growatt MOD 12KTL3-X vs Deye SUN-12K-G03
VS
The verdict
MOD 12KTL3-X leads on the differences that matter
The largest is european efficiency: 0.7 pp more efficient. 8 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.
See all 16 differencesHow alike are they
8
of 24 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
16 of 24 parameters
What actually differs
Parameter
MOD 12KTL3-X
SUN-12K-G03
Difference
European efficiency
98.2 %
97.5 %
0.7 pp more efficient
Max DC voltage
1100 V
1000 V
100 V apart
Max input current per tracker
26.0 A
13.0 A
13.0 A more headroom
Max AC power
12.00 kW
13.20 kW
1.20 kW apart
Max PV power
18.00 kW
15.60 kW
2.40 kW apart
Weight
14.0 kg
11.0 kg
3.0 kg lighter
DC/AC ratio
1.50
1.30
0.20 more oversizing headroom
Max efficiency
98.6 %
98.3 %
0.3 pp more efficient
Max operating temperature
60 °C
65 °C
5 °C more heat tolerant
Ingress protection
IP66
IP65
IP66 vs IP65
Weight per kW
1.2 kg/kW
0.9 kg/kW
0.2 kg/kW lighter
MPPT voltage range
140-1000 V
120-850 V
140-1000 V vs 120-850 V
Start voltage
160 V
140 V
20 V earlier start
Max AC current
20.0 A
19.1 A
0.9 A apart
Strings per tracker
2
1
1 string apart
Dimensions
387x425x178 mm
457x330x205 mm
387x425x178 mm vs 457x330x205 mm
02
Full specification
Parameter
MOD 12KTL3-X
SUN-12K-G03
Difference
AC output
Rated AC power
12.00 kW
12.00 kW
Same
Max AC power
12.00 kW
13.20 kW
1.20 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
20.0 A
19.1 A
0.9 A apart
PV input
Max PV power
18.00 kW
15.60 kW
2.40 kW apart
DC/AC ratio
1.50
1.30
+0.20 for MOD 12KTL3-X
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
140-1000 V
120-850 V
140-1000 V vs 120-850 V
Start voltage
160 V
140 V
-20 V for SUN-12K-G03
MPP trackers
2
2
Same
Strings per tracker
2
1
1 string apart
Max input current per tracker
26.0 A
13.0 A
+13.0 A for MOD 12KTL3-X
Efficiency
European efficiency
98.2 %
97.5 %
+0.7 pp for MOD 12KTL3-X
Max efficiency
98.6 %
98.3 %
+0.3 pp for MOD 12KTL3-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
14.0 kg
11.0 kg
-3.0 kg for SUN-12K-G03
Weight per kW
1.2 kg/kW
0.9 kg/kW
-0.2 kg/kW for SUN-12K-G03
Dimensions
387x425x178 mm
457x330x205 mm
387x425x178 mm vs 457x330x205 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
-
25 dB
Not published by Growatt
Max operating temperature
60 °C
65 °C
+5 °C for SUN-12K-G03
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by Deye
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Deye
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MOD 12KTL3-X vs Growatt MOD 12KTL3-X2(Pro)
4 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MOD 12KTL3-X vs Sungrow SG12KTL-M
8 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MOD 12KTL3-X vs Sungrow SG12RT-20
9 differences, the largest is weight
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.