Skip to main content
MOD 10KTL3-X2(Pro) vs MIN 10000TL-X 10 of 23 identical Swap Change inverters

Growatt MOD 10KTL3-X2(Pro) vs Growatt MIN 10000TL-X

Growatt MOD 10KTL3-X2(Pro)
Growatt
MOD 10KTL3-X2(Pro)
10 kW 98.2 % euro Grid-tie
VS
Growatt MIN 10000TL-X
Growatt
MIN 10000TL-X
10 kW 97.6 % euro Grid-tie
The verdict

MOD 10KTL3-X2(Pro) leads on the differences that matter

The largest is european efficiency: 0.6 pp more efficient. 10 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.

See all 13 differences
How alike are they
10 of 23 comparable
parameters are identical
identical differs not published
01

What actually differs

13 of 23 parameters
Parameter MOD 10KTL3-X2(Pro) MIN 10000TL-X Difference
European efficiency 98.2 % 97.6 % 0.6 pp more efficient
Max DC voltage 1100 V 600 V 500 V apart
Max input current per tracker 20.0 A 27.0 A 7.0 A more headroom
Warranty 8 yrs 5 yrs 3 yrs longer
Weight 14.6 kg 18.2 kg 3.6 kg lighter
Max efficiency 98.6 % 98.1 % 0.5 pp more efficient
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 240 V 160 V apart
Max AC current 16.0 A 45.5 A 29.5 A apart
Start voltage 160 V 100 V 60 V earlier start
Weight per kW 1.5 kg/kW 1.8 kg/kW 0.4 kg/kW lighter
MPPT voltage range 140-1000 V 60-550 V 140-1000 V vs 60-550 V
Dimensions 387x425x178 mm 387x425x180 mm 387x425x178 mm vs 387x425x180 mm
02

Full specification

Parameter MOD 10KTL3-X2(Pro) MIN 10000TL-X Difference
AC output
Rated AC power 10.00 kW 10.00 kW Same
Max AC power 10.00 kW 10.00 kW Same
Grid connection 3-phase Single-phase 3-phase vs Single-phase
Nominal AC voltage 400 V 240 V 160 V apart
Max AC current 16.0 A 45.5 A 29.5 A apart
PV input
Max PV power 15.00 kW 15.00 kW Same
DC/AC ratio 1.50 1.50 Same
Max DC voltage 1100 V 600 V 500 V apart
MPPT voltage range 140-1000 V 60-550 V 140-1000 V vs 60-550 V
Start voltage 160 V 100 V -60 V for MIN 10000TL-X
MPP trackers 2 - Not published by Growatt
Strings per tracker 1 - Not published by Growatt
Max input current per tracker 20.0 A 27.0 A +7.0 A for MIN 10000TL-X
Efficiency
European efficiency 98.2 % 97.6 % +0.6 pp for MOD 10KTL3-X2(Pro)
Max efficiency 98.6 % 98.1 % +0.5 pp for MOD 10KTL3-X2(Pro)
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 14.6 kg 18.2 kg -3.6 kg for MOD 10KTL3-X2(Pro)
Weight per kW 1.5 kg/kW 1.8 kg/kW -0.4 kg/kW for MOD 10KTL3-X2(Pro)
Dimensions 387x425x178 mm 387x425x180 mm 387x425x178 mm vs 387x425x180 mm
Ingress protection IP66 IP66 Same
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes Yes Same
Integrated DC switch - Yes Not published by Growatt
Warranty
Warranty 8 yrs 5 yrs +3 yrs for MOD 10KTL3-X2(Pro)
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt MOD 10KTL3-X2(Pro) vs Growatt MOD 10KTL3-X
5 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MOD 10KTL3-X2(Pro) vs Sungrow SG10KTL-M
8 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MOD 10KTL3-X2(Pro) vs Sungrow SG10RT-20
9 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.