Growatt MOD 10KTL3-HU vs Growatt SPH 10000TL-HU
VS
The verdict
MOD 10KTL3-HU leads on the differences that matter
The largest is warranty: 5 yrs longer. 9 of 28 comparable parameters are identical, with 4 more left out because at least one datasheet does not publish them.
See all 19 differencesHow alike are they
9
of 28 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
19 of 28 parameters
What actually differs
Parameter
MOD 10KTL3-HU
SPH 10000TL-HU
Difference
Warranty
10 yrs
5 yrs
5 yrs longer
Max DC voltage
1000 V
525 V
475 V apart
Max input current per tracker
20.0 A
22.0 A
2.0 A more headroom
Max efficiency
98.6 %
97.5 %
1.1 pp more efficient
Max PV power
20.00 kW
15.00 kW
5.00 kW apart
DC/AC ratio
2.00
1.50
0.50 more oversizing headroom
Max charge current
25 A
200 A
175 A faster charging
Weight
20.0 kg
48.8 kg
28.8 kg lighter
Weight per kW
2.0 kg/kW
4.9 kg/kW
2.9 kg/kW lighter
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
16.7 A
50.0 A
33.3 A apart
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
140-1000 V
150-450 V
140-1000 V vs 150-450 V
Battery voltage
600-980V
40-60V
600-980V vs 40-60V
Start voltage
160 V
150 V
10 V earlier start
Strings per tracker
1
2
1 string apart
Dimensions
480x468x202 mm
883x440x254 mm
480x468x202 mm vs 883x440x254 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
MOD 10KTL3-HU
SPH 10000TL-HU
Difference
AC output
Rated AC power
10.00 kW
10.00 kW
Same
Max AC power
10.00 kW
10.00 kW
Same
Grid connection
3-phase
Single-phase
3-phase vs Single-phase
Nominal AC voltage
400 V
230 V
170 V apart
Max AC current
16.7 A
50.0 A
33.3 A apart
PV input
Max PV power
20.00 kW
15.00 kW
5.00 kW apart
DC/AC ratio
2.00
1.50
+0.50 for MOD 10KTL3-HU
Max DC voltage
1000 V
525 V
475 V apart
MPPT voltage range
140-1000 V
150-450 V
140-1000 V vs 150-450 V
Start voltage
160 V
150 V
-10 V for SPH 10000TL-HU
MPP trackers
3
3
Same
Strings per tracker
1
2
1 string apart
Max input current per tracker
20.0 A
22.0 A
+2.0 A for SPH 10000TL-HU
Efficiency
European efficiency
98.1 %
-
Not published by Growatt
Max efficiency
98.6 %
97.5 %
+1.1 pp for MOD 10KTL3-HU
CEC efficiency
-
97.0 %
Not published by Growatt
Battery
Battery input
Yes
Yes
Same
Battery voltage
600-980V
40-60V
600-980V vs 40-60V
Max charge current
25 A
200 A
+175 A for SPH 10000TL-HU
Backup power
-
10.0 kW
Not published by Growatt
Physical
Weight
20.0 kg
48.8 kg
-28.8 kg for MOD 10KTL3-HU
Weight per kW
2.0 kg/kW
4.9 kg/kW
-2.9 kg/kW for MOD 10KTL3-HU
Dimensions
480x468x202 mm
883x440x254 mm
480x468x202 mm vs 883x440x254 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
forced-air
natural vs forced-air
Noise
29 dB
30 dB
Effectively the same
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
10 yrs
5 yrs
+5 yrs for MOD 10KTL3-HU
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt MOD 10KTL3-HU vs SolarEdge SE10000H
8 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 10KTL3-HU vs Growatt MOD 10KTL3-XH
9 differences, the largest is warranty
Same type, similar size
Huawei
Growatt MOD 10KTL3-HU vs Huawei SUN2000-10KTL-M1
14 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.