Parameter
MIN 9000TL-X
SG9.0RS-L
Difference
Max input current per tracker
27.0 A
16.0 A
11.0 A more headroom
European efficiency
97.6 %
97.4 %
0.2 pp more efficient
Max efficiency
98.1 %
97.8 %
0.3 pp more efficient
Max AC current
43.0 A
41.0 A
2.0 A apart
Start voltage
100 V
50 V
50 V earlier start
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
60-550 V
40-560 V
60-550 V vs 40-560 V
Dimensions
387x425x180 mm
365x525x170 mm
387x425x180 mm vs 365x525x170 mm
02
Full specification
Parameter
MIN 9000TL-X
SG9.0RS-L
Difference
AC output
Rated AC power
9.00 kW
9.00 kW
Same
Max AC power
9.00 kW
9.00 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
240 V
-
Not published by Sungrow
Max AC current
43.0 A
41.0 A
2.0 A apart
PV input
Max PV power
13.50 kW
13.50 kW
Same
DC/AC ratio
1.50
1.50
Same
Max DC voltage
600 V
600 V
Same
MPPT voltage range
60-550 V
40-560 V
60-550 V vs 40-560 V
Start voltage
100 V
50 V
-50 V for SG9.0RS-L
MPP trackers
-
3
Not published by Growatt
Strings per tracker
-
1
Not published by Growatt
Max input current per tracker
27.0 A
16.0 A
+11.0 A for MIN 9000TL-X
Efficiency
European efficiency
97.6 %
97.4 %
+0.2 pp for MIN 9000TL-X
Max efficiency
98.1 %
97.8 %
+0.3 pp for MIN 9000TL-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
18.2 kg
18.0 kg
Effectively the same
Weight per kW
2.0 kg/kW
2.0 kg/kW
Same
Dimensions
387x425x180 mm
365x525x170 mm
387x425x180 mm vs 365x525x170 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Sungrow
Arc fault protection
Yes
-
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Sungrow
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MIN 9000TL-X vs Growatt MOD 9000TL3-X
12 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MIN 9000TL-X vs Ginlong Solis S6-GR3P-9K02-NV-ND
11 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Growatt MIN 9000TL-X vs Solis-3P9K-4G
13 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.