MIN 9000TL-X
vs
SE16K (Delta grid version; part no. SExxK-xxxxxbxx4)
7 of 20 identical
Swap
Change inverters
Growatt MIN 9000TL-X vs SolarEdge SE16K (Delta grid version; part no. SExxK-xxxxxbxx4)
VS

SolarEdge
SE16K (Delta grid version; part no. SExxK-xxxxxbxx4)
9.2 kW
97.7 % euro
Grid-tie
The verdict
MIN 9000TL-X leads on the differences that matter
The largest is rated ac power: 0.20 kW apart. 7 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
7
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 20 parameters
What actually differs
Parameter
MIN 9000TL-X
SE16K (Delta grid version; part no. SExxK-xxxxxbxx4)
Difference
Rated AC power
9.00 kW
9.20 kW
0.20 kW apart
Max PV power
13.50 kW
12.42 kW
1.08 kW apart
Weight
18.2 kg
30.7 kg
12.5 kg lighter
Weight per kW
2.0 kg/kW
3.3 kg/kW
1.3 kg/kW lighter
Max AC power
9.00 kW
9.20 kW
0.20 kW apart
DC/AC ratio
1.50
1.35
0.15 more oversizing headroom
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Max AC current
43.0 A
25.5 A
17.5 A apart
Ingress protection
IP66
IP65
IP66 vs IP65
Nominal AC voltage
240 V
230 V
10 V apart
MPPT voltage range
60-550 V
370-600 V
60-550 V vs 370-600 V
Dimensions
387x425x180 mm
540x315x260 mm
387x425x180 mm vs 540x315x260 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
MIN 9000TL-X
SE16K (Delta grid version; part no. SExxK-xxxxxbxx4)
Difference
AC output
Rated AC power
9.00 kW
9.20 kW
0.20 kW apart
Max AC power
9.00 kW
9.20 kW
0.20 kW apart
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
240 V
230 V
10 V apart
Max AC current
43.0 A
25.5 A
17.5 A apart
PV input
Max PV power
13.50 kW
12.42 kW
1.08 kW apart
DC/AC ratio
1.50
1.35
+0.15 for MIN 9000TL-X
Max DC voltage
600 V
600 V
Same
MPPT voltage range
60-550 V
370-600 V
60-550 V vs 370-600 V
Start voltage
100 V
-
Not published by SolarEdge
MPP trackers
-
-
Neither datasheet publishes this
Strings per tracker
-
-
Neither datasheet publishes this
Max input current per tracker
27.0 A
-
Not published by SolarEdge
Efficiency
European efficiency
97.6 %
97.7 %
Effectively the same
Max efficiency
98.1 %
98.0 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
18.2 kg
30.7 kg
-12.5 kg for MIN 9000TL-X
Weight per kW
2.0 kg/kW
3.3 kg/kW
-1.3 kg/kW for MIN 9000TL-X
Dimensions
387x425x180 mm
540x315x260 mm
387x425x180 mm vs 540x315x260 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
forced-air
natural vs forced-air
Noise
-
50 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
-
Not published by SolarEdge
Warranty
Warranty
5 yrs
-
Not published by SolarEdge
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MIN 9000TL-X vs Growatt MOD 9000TL3-X
12 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MIN 9000TL-X vs Ginlong Solis S6-GR3P-9K02-NV-ND
11 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Growatt MIN 9000TL-X vs Solis-3P9K-4G
13 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.