Skip to main content
MIN 7000TL-X(E) vs MOD 7000TL3-X 9 of 23 identical Swap Change inverters

Growatt MIN 7000TL-X(E) vs Growatt MOD 7000TL3-X

Growatt MIN 7000TL-X(E)
Growatt
MIN 7000TL-X(E)
7 kW 97.3 % euro Grid-tie
VS
Growatt MOD 7000TL3-X
Growatt
MOD 7000TL3-X
7 kW 98.1 % euro Grid-tie
The verdict

MOD 7000TL3-X leads on the differences that matter

The largest is european efficiency: 0.8 pp more efficient. 9 of 23 comparable parameters are identical, with 9 more left out because at least one datasheet does not publish them.

See all 14 differences
How alike are they
9 of 23 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 23 parameters
Parameter MIN 7000TL-X(E) MOD 7000TL3-X Difference
European efficiency 97.3 % 98.1 % 0.8 pp more efficient
Max DC voltage 600 V 1100 V 500 V apart
Max input current per tracker 27.0 A 13.0 A 14.0 A more headroom
Max PV power 12.00 kW 10.50 kW 1.50 kW apart
DC/AC ratio 1.71 1.50 0.21 more oversizing headroom
Weight 18.2 kg 14.0 kg 4.2 kg lighter
Max efficiency 98.1 % 98.6 % 0.5 pp more efficient
Weight per kW 2.6 kg/kW 2.0 kg/kW 0.6 kg/kW lighter
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 240 V 400 V 160 V apart
Max AC current 33.5 A 11.7 A 21.8 A apart
Start voltage 100 V 160 V 60 V earlier start
MPPT voltage range 60-550 V 140-1000 V 60-550 V vs 140-1000 V
Dimensions 387x425x180 mm 387x425x147 mm 387x425x180 mm vs 387x425x147 mm
02

Full specification

Parameter MIN 7000TL-X(E) MOD 7000TL3-X Difference
AC output
Rated AC power 7.00 kW 7.00 kW Same
Max AC power 7.00 kW 7.00 kW Same
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 240 V 400 V 160 V apart
Max AC current 33.5 A 11.7 A 21.8 A apart
PV input
Max PV power 12.00 kW 10.50 kW 1.50 kW apart
DC/AC ratio 1.71 1.50 +0.21 for MIN 7000TL-X(E)
Max DC voltage 600 V 1100 V 500 V apart
MPPT voltage range 60-550 V 140-1000 V 60-550 V vs 140-1000 V
Start voltage 100 V 160 V -60 V for MIN 7000TL-X(E)
MPP trackers - 2 Not published by Growatt
Strings per tracker - 1 Not published by Growatt
Max input current per tracker 27.0 A 13.0 A +14.0 A for MIN 7000TL-X(E)
Efficiency
European efficiency 97.3 % 98.1 % +0.8 pp for MOD 7000TL3-X
Max efficiency 98.1 % 98.6 % +0.5 pp for MOD 7000TL3-X
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 18.2 kg 14.0 kg -4.2 kg for MOD 7000TL3-X
Weight per kW 2.6 kg/kW 2.0 kg/kW -0.6 kg/kW for MOD 7000TL3-X
Dimensions 387x425x180 mm 387x425x147 mm 387x425x180 mm vs 387x425x147 mm
Ingress protection IP66 IP66 Same
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes - Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs 5 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt MIN 7000TL-X(E) vs Growatt MOD 7KTL3-X2(Pro)
15 differences, the largest is european efficiency
Same type, similar size
Sungrow
Growatt MIN 7000TL-X(E) vs Sungrow SG5.0RT
15 differences, the largest is max dc voltage
Same type, similar size
Sungrow
Growatt MIN 7000TL-X(E) vs Sungrow SG7.0RT-P2
13 differences, the largest is max dc voltage
Same type, similar size
Deye
Growatt MOD 7000TL3-X vs Deye SUN-7K-G03
14 differences, the largest is european efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.