Skip to main content
MIN 6000TL-XH vs SUN2000-6KTL-M1 11 of 28 identical Swap Change inverters

Growatt MIN 6000TL-XH vs Huawei SUN2000-6KTL-M1

Growatt MIN 6000TL-XH
Growatt
MIN 6000TL-XH
6 kW 97.5 % euro Hybrid
VS
Huawei SUN2000-6KTL-M1
Huawei
SUN2000-6KTL-M1
6 kW 97.7 % euro Hybrid
The verdict

MIN 6000TL-XH leads on the differences that matter

The largest is max dc voltage: 550 V apart. 11 of 28 comparable parameters are identical, with 4 more left out because at least one datasheet does not publish them.

See all 17 differences
How alike are they
11 of 28 comparable
parameters are identical
identical differs not published
01

What actually differs

17 of 28 parameters
Parameter MIN 6000TL-XH SUN2000-6KTL-M1 Difference
Max DC voltage 550 V 1100 V 550 V apart
Max input current per tracker 13.5 A 11.0 A 2.5 A more headroom
Max AC power 6.00 kW 6.60 kW 0.60 kW apart
Max PV power 10.00 kW 9.00 kW 1.00 kW apart
Weight 10.8 kg 17.0 kg 6.2 kg lighter
Weight per kW 1.8 kg/kW 2.8 kg/kW 1.0 kg/kW lighter
DC/AC ratio 1.67 1.50 0.17 more oversizing headroom
European efficiency 97.5 % 97.7 % 0.2 pp more efficient
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 27.2 A 10.1 A 17.1 A apart
Start voltage 100 V 200 V 100 V earlier start
Max efficiency 98.4 % 98.6 % 0.2 pp more efficient
MPPT voltage range 70-550 V 140-980 V 70-550 V vs 140-980 V
Battery voltage 360-550V 600 V ~ 980 V 360-550V vs 600 V ~ 980 V
Max charge current 17 A 16 A 1 A faster charging
Dimensions 350x375x160 mm 525x470x146 mm 350x375x160 mm vs 525x470x146 mm
02

Full specification

Parameter MIN 6000TL-XH SUN2000-6KTL-M1 Difference
AC output
Rated AC power 6.00 kW 6.00 kW Same
Max AC power 6.00 kW 6.60 kW 0.60 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 27.2 A 10.1 A 17.1 A apart
PV input
Max PV power 10.00 kW 9.00 kW 1.00 kW apart
DC/AC ratio 1.67 1.50 +0.17 for MIN 6000TL-XH
Max DC voltage 550 V 1100 V 550 V apart
MPPT voltage range 70-550 V 140-980 V 70-550 V vs 140-980 V
Start voltage 100 V 200 V -100 V for MIN 6000TL-XH
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 13.5 A 11.0 A +2.5 A for MIN 6000TL-XH
Efficiency
European efficiency 97.5 % 97.7 % +0.2 pp for SUN2000-6KTL-M1
Max efficiency 98.4 % 98.6 % +0.2 pp for SUN2000-6KTL-M1
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 360-550V 600 V ~ 980 V 360-550V vs 600 V ~ 980 V
Max charge current 17 A 16 A +1 A for MIN 6000TL-XH
Backup power - 3.3 kW Not published by Growatt
Physical
Weight 10.8 kg 17.0 kg -6.2 kg for MIN 6000TL-XH
Weight per kW 1.8 kg/kW 2.8 kg/kW -1.0 kg/kW for MIN 6000TL-XH
Dimensions 350x375x160 mm 525x470x146 mm 350x375x160 mm vs 525x470x146 mm
Ingress protection IP65 IP65 Same
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by Huawei
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MIN 6000TL-XH vs SolarEdge SE6000H
8 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MIN 6000TL-XH vs Growatt MOD 6000TL3-HU
18 differences, the largest is warranty
Same type, similar size
Huawei
Growatt MIN 6000TL-XH vs Huawei SUN2000-6KTL-L1
11 differences, the largest is max dc voltage
Same type, similar size
Huawei
Huawei SUN2000-6KTL-M1 vs Huawei SUN2000-6KTL-M1 (High current version)
2 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.