Skip to main content
MIN 5000TL-X2 (Pro) vs Solis-3P5K-4G 5 of 19 identical Swap Change inverters

Growatt MIN 5000TL-X2 (Pro) vs Solis-3P5K-4G

Growatt MIN 5000TL-X2 (Pro)
Growatt
MIN 5000TL-X2 (Pro)
5 kW 97.5 % euro Grid-tie
VS
Ginlong Solis
Solis-3P5K-4G
5 kW 97.8 % euro Grid-tie
The verdict

MIN 5000TL-X2 (Pro) leads on the differences that matter

The largest is max dc voltage: 450 V apart. 5 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.

See all 14 differences
How alike are they
5 of 19 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 19 parameters
Parameter MIN 5000TL-X2 (Pro) Solis-3P5K-4G Difference
Max DC voltage 550 V 1000 V 450 V apart
Max AC power 5.00 kW 5.50 kW 0.50 kW apart
Max PV power 7.50 kW 6.00 kW 1.50 kW apart
DC/AC ratio 1.50 1.20 0.30 more oversizing headroom
Weight 10.8 kg 18.0 kg 7.2 kg lighter
Weight per kW 2.2 kg/kW 3.6 kg/kW 1.4 kg/kW lighter
European efficiency 97.5 % 97.8 % 0.3 pp more efficient
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 22.7 A 7.9 A 14.8 A apart
Start voltage 50 V 180 V 130 V earlier start
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 40-550 V 160-850 V 40-550 V vs 160-850 V
Dimensions 350x375x158 mm 563x310x219 mm 350x375x158 mm vs 563x310x219 mm
02

Full specification

Parameter MIN 5000TL-X2 (Pro) Solis-3P5K-4G Difference
AC output
Rated AC power 5.00 kW 5.00 kW Same
Max AC power 5.00 kW 5.50 kW 0.50 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 22.7 A 7.9 A 14.8 A apart
PV input
Max PV power 7.50 kW 6.00 kW 1.50 kW apart
DC/AC ratio 1.50 1.20 +0.30 for MIN 5000TL-X2 (Pro)
Max DC voltage 550 V 1000 V 450 V apart
MPPT voltage range 40-550 V 160-850 V 40-550 V vs 160-850 V
Start voltage 50 V 180 V -130 V for MIN 5000TL-X2 (Pro)
MPP trackers 2 2 Same
Strings per tracker 1 - Not published by Ginlong Solis
Max input current per tracker 18.0 A - Not published by Ginlong Solis
Efficiency
European efficiency 97.5 % 97.8 % +0.3 pp for Solis-3P5K-4G
Max efficiency 98.4 % 98.3 % Effectively the same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 10.8 kg 18.0 kg -7.2 kg for MIN 5000TL-X2 (Pro)
Weight per kW 2.2 kg/kW 3.6 kg/kW -1.4 kg/kW for MIN 5000TL-X2 (Pro)
Dimensions 350x375x158 mm 563x310x219 mm 350x375x158 mm vs 563x310x219 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural - Not published by Ginlong Solis
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by Growatt
Integrated DC switch - Yes Not published by Growatt
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MIN 5000TL-X2 (Pro) vs SolarEdge SE5000H (HD‑Wave, single phase)
9 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Growatt MIN 5000TL-X2 (Pro) vs SolarEdge EV Charging Single Phase Inverter SE5000H (aka H5000SE / SE5000H)
8 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MIN 5000TL-X2 (Pro) vs Ginlong Solis S6-GR3P-5K02-NV-ND
10 differences, the largest is max dc voltage
Same type, similar size
GoodWe
Solis-3P5K-4G vs GoodWe GW5K-DT
6 differences, the largest is weight
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.