Growatt MIN 5000TL-X vs Ginlong Solis S6-GR3P-5K02-NV-ND
VS
The verdict
14 differences, and they point both ways
The largest is european efficiency: 0.5 pp more efficient. 7 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.
See all 14 differencesHow alike are they
7
of 21 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
14 of 21 parameters
What actually differs
Parameter
MIN 5000TL-X
S6-GR3P-5K02-NV-ND
Difference
European efficiency
97.2 %
97.7 %
0.5 pp more efficient
Max DC voltage
550 V
1100 V
550 V apart
Max input current per tracker
12.5 A
21.0 A
8.5 A more headroom
Max AC power
5.50 kW
5.00 kW
0.50 kW apart
Max PV power
7.00 kW
7.50 kW
0.50 kW apart
Weight
10.8 kg
14.7 kg
3.9 kg lighter
Weight per kW
2.2 kg/kW
2.9 kg/kW
0.8 kg/kW lighter
DC/AC ratio
1.40
1.50
0.10 more oversizing headroom
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Max AC current
23.9 A
7.6 A
16.3 A apart
Start voltage
100 V
160 V
60 V earlier start
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
80-550 V
160-1000 V
80-550 V vs 160-1000 V
Dimensions
350x375x158 mm
410x355x179 mm
350x375x158 mm vs 410x355x179 mm
02
Full specification
Parameter
MIN 5000TL-X
S6-GR3P-5K02-NV-ND
Difference
AC output
Rated AC power
5.00 kW
5.00 kW
Same
Max AC power
5.50 kW
5.00 kW
0.50 kW apart
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
220 V
-
Not published by Ginlong Solis
Max AC current
23.9 A
7.6 A
16.3 A apart
PV input
Max PV power
7.00 kW
7.50 kW
0.50 kW apart
DC/AC ratio
1.40
1.50
+0.10 for S6-GR3P-5K02-NV-ND
Max DC voltage
550 V
1100 V
550 V apart
MPPT voltage range
80-550 V
160-1000 V
80-550 V vs 160-1000 V
Start voltage
100 V
160 V
-60 V for MIN 5000TL-X
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
12.5 A
21.0 A
+8.5 A for S6-GR3P-5K02-NV-ND
Efficiency
European efficiency
97.2 %
97.7 %
+0.5 pp for S6-GR3P-5K02-NV-ND
Max efficiency
98.4 %
98.3 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
14.7 kg
-3.9 kg for MIN 5000TL-X
Weight per kW
2.2 kg/kW
2.9 kg/kW
-0.8 kg/kW for MIN 5000TL-X
Dimensions
350x375x158 mm
410x355x179 mm
350x375x158 mm vs 410x355x179 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
natural
Same
Noise
-
30 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Ginlong Solis
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt MIN 5000TL-X vs SolarEdge SE5000H (HD‑Wave, single phase)
12 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Growatt MIN 5000TL-X vs SolarEdge EV Charging Single Phase Inverter SE5000H (aka H5000SE / SE5000H)
10 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MIN 5000TL-X vs Solis-3P5K-4G
12 differences, the largest is european efficiency
Same type, similar size
GoodWe
Ginlong Solis S6-GR3P-5K02-NV-ND vs GoodWe GW5K-DT
6 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.