Skip to main content
MIN 5000TL-X vs S6-GR3P-5K02-NV-ND 7 of 21 identical Swap Change inverters

Growatt MIN 5000TL-X vs Ginlong Solis S6-GR3P-5K02-NV-ND

Growatt MIN 5000TL-X
Growatt
MIN 5000TL-X
5 kW 97.2 % euro Grid-tie
VS
Ginlong Solis S6-GR3P-5K02-NV-ND
Ginlong Solis
S6-GR3P-5K02-NV-ND
5 kW 97.7 % euro Grid-tie
The verdict

14 differences, and they point both ways

The largest is european efficiency: 0.5 pp more efficient. 7 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.

See all 14 differences
How alike are they
7 of 21 comparable
parameters are identical
identical differs not published
01

What actually differs

14 of 21 parameters
Parameter MIN 5000TL-X S6-GR3P-5K02-NV-ND Difference
European efficiency 97.2 % 97.7 % 0.5 pp more efficient
Max DC voltage 550 V 1100 V 550 V apart
Max input current per tracker 12.5 A 21.0 A 8.5 A more headroom
Max AC power 5.50 kW 5.00 kW 0.50 kW apart
Max PV power 7.00 kW 7.50 kW 0.50 kW apart
Weight 10.8 kg 14.7 kg 3.9 kg lighter
Weight per kW 2.2 kg/kW 2.9 kg/kW 0.8 kg/kW lighter
DC/AC ratio 1.40 1.50 0.10 more oversizing headroom
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Max AC current 23.9 A 7.6 A 16.3 A apart
Start voltage 100 V 160 V 60 V earlier start
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 80-550 V 160-1000 V 80-550 V vs 160-1000 V
Dimensions 350x375x158 mm 410x355x179 mm 350x375x158 mm vs 410x355x179 mm
02

Full specification

Parameter MIN 5000TL-X S6-GR3P-5K02-NV-ND Difference
AC output
Rated AC power 5.00 kW 5.00 kW Same
Max AC power 5.50 kW 5.00 kW 0.50 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 220 V - Not published by Ginlong Solis
Max AC current 23.9 A 7.6 A 16.3 A apart
PV input
Max PV power 7.00 kW 7.50 kW 0.50 kW apart
DC/AC ratio 1.40 1.50 +0.10 for S6-GR3P-5K02-NV-ND
Max DC voltage 550 V 1100 V 550 V apart
MPPT voltage range 80-550 V 160-1000 V 80-550 V vs 160-1000 V
Start voltage 100 V 160 V -60 V for MIN 5000TL-X
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 12.5 A 21.0 A +8.5 A for S6-GR3P-5K02-NV-ND
Efficiency
European efficiency 97.2 % 97.7 % +0.5 pp for S6-GR3P-5K02-NV-ND
Max efficiency 98.4 % 98.3 % Effectively the same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 10.8 kg 14.7 kg -3.9 kg for MIN 5000TL-X
Weight per kW 2.2 kg/kW 2.9 kg/kW -0.8 kg/kW for MIN 5000TL-X
Dimensions 350x375x158 mm 410x355x179 mm 350x375x158 mm vs 410x355x179 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise - 30 dB Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by Ginlong Solis
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MIN 5000TL-X vs SolarEdge SE5000H (HD‑Wave, single phase)
12 differences, the largest is european efficiency
Same type, similar size
SolarEdge
Growatt MIN 5000TL-X vs SolarEdge EV Charging Single Phase Inverter SE5000H (aka H5000SE / SE5000H)
10 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MIN 5000TL-X vs Solis-3P5K-4G
12 differences, the largest is european efficiency
Same type, similar size
GoodWe
Ginlong Solis S6-GR3P-5K02-NV-ND vs GoodWe GW5K-DT
6 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.