Growatt MIN 4600TL-XH vs Fronius Primo GEN24 4.6 Plus
VS
Fronius International
Fronius Primo GEN24 4.6 Plus
4.6 kW
97.2 % euro
Hybrid
The verdict
MIN 4600TL-XH leads on the differences that matter
The largest is max dc voltage: 50 V apart. 11 of 27 comparable parameters are identical, with 5 more left out because at least one datasheet does not publish them.
See all 16 differencesHow alike are they
11
of 27 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
16 of 27 parameters
What actually differs
Parameter
MIN 4600TL-XH
Fronius Primo GEN24 4.6 Plus
Difference
Max DC voltage
550 V
600 V
50 V apart
Max input current per tracker
13.5 A
22.0 A
8.5 A more headroom
Max efficiency
98.4 %
97.6 %
0.8 pp more efficient
Max PV power
9.20 kW
4.75 kW
4.45 kW apart
DC/AC ratio
2.00
1.03
0.97 more oversizing headroom
Max charge current
17 A
22 A
5 A faster charging
Weight
10.8 kg
15.4 kg
4.6 kg lighter
Weight per kW
2.3 kg/kW
3.3 kg/kW
1.0 kg/kW lighter
European efficiency
97.5 %
97.2 %
0.3 pp more efficient
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
70-550 V
65-530 V
70-550 V vs 65-530 V
Start voltage
100 V
80 V
20 V earlier start
Battery voltage
360-550V
150-455 V
360-550V vs 150-455 V
Strings per tracker
1
2
1 string apart
Dimensions
350x375x160 mm
530x474x165 mm
350x375x160 mm vs 530x474x165 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
MIN 4600TL-XH
Fronius Primo GEN24 4.6 Plus
Difference
AC output
Rated AC power
4.60 kW
4.60 kW
Same
Max AC power
4.60 kW
4.60 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
20.9 A
20.9 A
Same
PV input
Max PV power
9.20 kW
4.75 kW
4.45 kW apart
DC/AC ratio
2.00
1.03
+0.97 for MIN 4600TL-XH
Max DC voltage
550 V
600 V
50 V apart
MPPT voltage range
70-550 V
65-530 V
70-550 V vs 65-530 V
Start voltage
100 V
80 V
-20 V for Fronius Primo GEN24 4.6 Plus
MPP trackers
2
2
Same
Strings per tracker
1
2
1 string apart
Max input current per tracker
13.5 A
22.0 A
+8.5 A for Fronius Primo GEN24 4.6 Plus
Efficiency
European efficiency
97.5 %
97.2 %
+0.3 pp for MIN 4600TL-XH
Max efficiency
98.4 %
97.6 %
+0.8 pp for MIN 4600TL-XH
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
360-550V
150-455 V
360-550V vs 150-455 V
Max charge current
17 A
22 A
+5 A for Fronius Primo GEN24 4.6 Plus
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
15.4 kg
-4.6 kg for MIN 4600TL-XH
Weight per kW
2.3 kg/kW
3.3 kg/kW
-1.0 kg/kW for MIN 4600TL-XH
Dimensions
350x375x160 mm
530x474x165 mm
350x375x160 mm vs 530x474x165 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
forced-air
natural vs forced-air
Noise
-
42 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by Fronius International
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Fronius International
03
Open all inverters
More useful comparisons
Same type, similar size
Huawei
Growatt MIN 4600TL-XH vs Huawei SUN2000L-4.6KTL
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MIN 4600TL-XH vs Huawei SUN2000-4.6KTL-L1
12 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MIN 4600TL-XH vs Growatt SPM 4600TL-HU
13 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.