Growatt MIN 4200TL-X2 (Pro) vs Growatt MIN 4200TL-X
VS
The verdict
MIN 4200TL-X2 (Pro) leads on the differences that matter
The largest is max input current per tracker: 5.5 A more headroom. 13 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 9 differencesHow alike are they
13
of 22 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
9 of 22 parameters
What actually differs
Parameter
MIN 4200TL-X2 (Pro)
MIN 4200TL-X
Difference
Max input current per tracker
18.0 A
12.5 A
5.5 A more headroom
Max AC power
4.20 kW
4.62 kW
0.42 kW apart
Max PV power
6.30 kW
5.88 kW
0.42 kW apart
DC/AC ratio
1.50
1.40
0.10 more oversizing headroom
Start voltage
50 V
100 V
50 V earlier start
Ingress protection
IP66
IP65
IP66 vs IP65
Nominal AC voltage
230 V
220 V
10 V apart
Max AC current
19.0 A
20.0 A
1.0 A apart
MPPT voltage range
40-550 V
80-550 V
40-550 V vs 80-550 V
02
Full specification
Parameter
MIN 4200TL-X2 (Pro)
MIN 4200TL-X
Difference
AC output
Rated AC power
4.20 kW
4.20 kW
Same
Max AC power
4.20 kW
4.62 kW
0.42 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
220 V
10 V apart
Max AC current
19.0 A
20.0 A
1.0 A apart
PV input
Max PV power
6.30 kW
5.88 kW
0.42 kW apart
DC/AC ratio
1.50
1.40
+0.10 for MIN 4200TL-X2 (Pro)
Max DC voltage
550 V
550 V
Same
MPPT voltage range
40-550 V
80-550 V
40-550 V vs 80-550 V
Start voltage
50 V
100 V
-50 V for MIN 4200TL-X2 (Pro)
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
18.0 A
12.5 A
+5.5 A for MIN 4200TL-X2 (Pro)
Efficiency
European efficiency
97.2 %
97.1 %
Effectively the same
Max efficiency
98.4 %
98.4 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
10.8 kg
Same
Weight per kW
2.6 kg/kW
2.6 kg/kW
Same
Dimensions
350x375x158 mm
350x375x158 mm
Same
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
-
Yes
Not published by Growatt
Warranty
Warranty
-
5 yrs
Not published by Growatt
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MIN 4200TL-X2 (Pro) vs Growatt MIN 4200TL-X2 (Pro E)
2 differences, the largest is mpp trackers
Same type, similar size
SolarEdge
Growatt MIN 4200TL-X2 (Pro) vs SolarEdge EV Charging Single Phase Inverter SE4000H (aka H4000SE / SE4000H)
12 differences, the largest is rated ac power
Same type, similar size
SolarEdge
Growatt MIN 4200TL-X2 (Pro) vs SolarEdge SE4000H (HD‑Wave, single phase)
12 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.