Skip to main content
MIN 3600TL-XH2 vs GW3600-ES-C10 13 of 24 identical Swap Change inverters

Growatt MIN 3600TL-XH2 vs GoodWe GW3600-ES-C10

Growatt MIN 3600TL-XH2
Growatt
MIN 3600TL-XH2
3.6 kW 97.2 % euro Hybrid
VS
GoodWe GW3600-ES-C10
GoodWe
GW3600-ES-C10
3.6 kW Hybrid
The verdict

MIN 3600TL-XH2 leads on the differences that matter

The largest is max dc voltage: 50 V apart. 13 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
13 of 24 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 24 parameters
Parameter MIN 3600TL-XH2 GW3600-ES-C10 Difference
Max DC voltage 550 V 600 V 50 V apart
Max input current per tracker 16.0 A 32.0 A 16.0 A more headroom
Max efficiency 98.2 % 97.6 % 0.6 pp more efficient
Max AC power 3.60 kW 3.96 kW 0.36 kW apart
Weight 10.8 kg 15.5 kg 4.7 kg lighter
Weight per kW 3.0 kg/kW 4.3 kg/kW 1.3 kg/kW lighter
Max AC current 16.0 A 18.0 A 2.0 A apart
MPPT voltage range 40-540 V 60-550 V 40-540 V vs 60-550 V
Battery voltage 360-550 V 40~60 V 360-550 V vs 40~60 V
Dimensions 350x375x160 mm 415x560x204 mm 350x375x160 mm vs 415x560x204 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter MIN 3600TL-XH2 GW3600-ES-C10 Difference
AC output
Rated AC power 3.60 kW 3.60 kW Same
Max AC power 3.60 kW 3.96 kW 0.36 kW apart
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 16.0 A 18.0 A 2.0 A apart
PV input
Max PV power 7.20 kW 7.20 kW Same
DC/AC ratio 2.00 2.00 Same
Max DC voltage 550 V 600 V 50 V apart
MPPT voltage range 40-540 V 60-550 V 40-540 V vs 60-550 V
Start voltage 50 V 58 V Effectively the same
MPP trackers 2 - Not published by GoodWe
Strings per tracker 1 - Not published by GoodWe
Max input current per tracker 16.0 A 32.0 A +16.0 A for GW3600-ES-C10
Efficiency
European efficiency 97.2 % - Not published by GoodWe
Max efficiency 98.2 % 97.6 % +0.6 pp for MIN 3600TL-XH2
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 360-550 V 40~60 V 360-550 V vs 40~60 V
Max charge current 17 A - Not published by GoodWe
Backup power - - Neither datasheet publishes this
Physical
Weight 10.8 kg 15.5 kg -4.7 kg for MIN 3600TL-XH2
Weight per kW 3.0 kg/kW 4.3 kg/kW -1.3 kg/kW for MIN 3600TL-XH2
Dimensions 350x375x160 mm 415x560x204 mm 350x375x160 mm vs 415x560x204 mm
Ingress protection IP66 IP66 Same
Cooling natural forced-air natural vs forced-air
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by GoodWe
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt MIN 3600TL-XH2 vs Growatt SPM 3600TL-HU
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MIN 3600TL-XH2 vs Growatt MIN 3600TL-XH
5 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Growatt MIN 3600TL-XH2 vs Growatt MIN 3600TL-XA
2 differences, the largest is warranty
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.