Growatt MIN 3600TL-XH2 vs Ginlong Solis RHI-3.6K-48ES-5G
VS
The verdict
MIN 3600TL-XH2 leads on the differences that matter
The largest is max dc voltage: 50 V apart. 11 of 26 comparable parameters are identical, with 6 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
11
of 26 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 26 parameters
What actually differs
Parameter
MIN 3600TL-XH2
RHI-3.6K-48ES-5G
Difference
Max DC voltage
550 V
600 V
50 V apart
Max input current per tracker
16.0 A
11.0 A
5.0 A more headroom
Max efficiency
98.2 %
97.5 %
0.7 pp more efficient
European efficiency
97.2 %
96.8 %
0.4 pp more efficient
Max charge current
17 A
100 A
83 A faster charging
Weight
10.8 kg
17.0 kg
6.2 kg lighter
Weight per kW
3.0 kg/kW
4.7 kg/kW
1.7 kg/kW lighter
Max PV power
7.20 kW
7.00 kW
0.20 kW apart
Start voltage
50 V
120 V
70 V earlier start
Ingress protection
IP66
IP65
IP66 vs IP65
Max AC current
16.0 A
17.3 A
1.3 A apart
DC/AC ratio
2.00
1.94
0.06 more oversizing headroom
MPPT voltage range
40-540 V
90-520 V
40-540 V vs 90-520 V
Battery voltage
360-550 V
42-58 V
360-550 V vs 42-58 V
Dimensions
350x375x160 mm
505x333x249 mm
350x375x160 mm vs 505x333x249 mm
02
Full specification
Parameter
MIN 3600TL-XH2
RHI-3.6K-48ES-5G
Difference
AC output
Rated AC power
3.60 kW
3.60 kW
Same
Max AC power
3.60 kW
3.60 kW
Same
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
16.0 A
17.3 A
1.3 A apart
PV input
Max PV power
7.20 kW
7.00 kW
0.20 kW apart
DC/AC ratio
2.00
1.94
+0.06 for MIN 3600TL-XH2
Max DC voltage
550 V
600 V
50 V apart
MPPT voltage range
40-540 V
90-520 V
40-540 V vs 90-520 V
Start voltage
50 V
120 V
-70 V for MIN 3600TL-XH2
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
16.0 A
11.0 A
+5.0 A for MIN 3600TL-XH2
Efficiency
European efficiency
97.2 %
96.8 %
+0.4 pp for MIN 3600TL-XH2
Max efficiency
98.2 %
97.5 %
+0.7 pp for MIN 3600TL-XH2
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
360-550 V
42-58 V
360-550 V vs 42-58 V
Max charge current
17 A
100 A
+83 A for RHI-3.6K-48ES-5G
Backup power
-
5.0 kW
Not published by Growatt
Physical
Weight
10.8 kg
17.0 kg
-6.2 kg for MIN 3600TL-XH2
Weight per kW
3.0 kg/kW
4.7 kg/kW
-1.7 kg/kW for MIN 3600TL-XH2
Dimensions
350x375x160 mm
505x333x249 mm
350x375x160 mm vs 505x333x249 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
natural
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Ginlong Solis
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
-
Not published by Ginlong Solis
Warranty
Warranty
5 yrs
-
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MIN 3600TL-XH2 vs Growatt SPM 3600TL-HU
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MIN 3600TL-XH2 vs Growatt MIN 3600TL-XH
5 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Growatt MIN 3600TL-XH2 vs Growatt MIN 3600TL-XA
2 differences, the largest is warranty
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.