Growatt MIN 3600TL-XH2 vs Deye SUN-3.6K-SG01/03LP1-EU
VS
The verdict
MIN 3600TL-XH2 leads on the differences that matter
The largest is european efficiency: 0.7 pp more efficient. 8 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.
See all 17 differencesHow alike are they
8
of 25 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
17 of 25 parameters
What actually differs
Parameter
MIN 3600TL-XH2
SUN-3.6K-SG01/03LP1-EU
Difference
European efficiency
97.2 %
96.5 %
0.7 pp more efficient
Max DC voltage
550 V
500 V
50 V apart
Max input current per tracker
16.0 A
11.0 A
5.0 A more headroom
Max efficiency
98.2 %
97.6 %
0.6 pp more efficient
Max AC power
3.60 kW
3.96 kW
0.36 kW apart
Max PV power
7.20 kW
4.68 kW
2.52 kW apart
DC/AC ratio
2.00
1.30
0.70 more oversizing headroom
Max charge current
17 A
120 A
103 A faster charging
Weight
10.8 kg
20.5 kg
9.7 kg lighter
Weight per kW
3.0 kg/kW
5.7 kg/kW
2.7 kg/kW lighter
Max AC current
16.0 A
18.0 A
2.0 A apart
Start voltage
50 V
150 V
100 V earlier start
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
40-540 V
125-425 V
40-540 V vs 125-425 V
Battery voltage
360-550 V
40-60 V
360-550 V vs 40-60 V
Dimensions
350x375x160 mm
580x330x232 mm
350x375x160 mm vs 580x330x232 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
MIN 3600TL-XH2
SUN-3.6K-SG01/03LP1-EU
Difference
AC output
Rated AC power
3.60 kW
3.60 kW
Same
Max AC power
3.60 kW
3.96 kW
0.36 kW apart
Grid connection
Single-phase
Single-phase
Same
Nominal AC voltage
230 V
230 V
Same
Max AC current
16.0 A
18.0 A
2.0 A apart
PV input
Max PV power
7.20 kW
4.68 kW
2.52 kW apart
DC/AC ratio
2.00
1.30
+0.70 for MIN 3600TL-XH2
Max DC voltage
550 V
500 V
50 V apart
MPPT voltage range
40-540 V
125-425 V
40-540 V vs 125-425 V
Start voltage
50 V
150 V
-100 V for MIN 3600TL-XH2
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
16.0 A
11.0 A
+5.0 A for MIN 3600TL-XH2
Efficiency
European efficiency
97.2 %
96.5 %
+0.7 pp for MIN 3600TL-XH2
Max efficiency
98.2 %
97.6 %
+0.6 pp for MIN 3600TL-XH2
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
Yes
Yes
Same
Battery voltage
360-550 V
40-60 V
360-550 V vs 40-60 V
Max charge current
17 A
120 A
+103 A for SUN-3.6K-SG01/03LP1-EU
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
10.8 kg
20.5 kg
-9.7 kg for MIN 3600TL-XH2
Weight per kW
3.0 kg/kW
5.7 kg/kW
-2.7 kg/kW for MIN 3600TL-XH2
Dimensions
350x375x160 mm
580x330x232 mm
350x375x160 mm vs 580x330x232 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
forced-air
natural vs forced-air
Noise
-
30 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Deye
Ethernet
Yes
-
Not published by Deye
Arc fault protection
Yes
-
Not published by Deye
Integrated DC switch
Yes
-
Not published by Deye
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MIN 3600TL-XH2 vs Growatt SPM 3600TL-HU
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MIN 3600TL-XH2 vs Growatt MIN 3600TL-XH
5 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Growatt MIN 3600TL-XH2 vs Growatt MIN 3600TL-XA
2 differences, the largest is warranty
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.