Skip to main content
MIN 3600TL-XH2 vs SUN-3.6K-SG01/03LP1-EU 8 of 25 identical Swap Change inverters

Growatt MIN 3600TL-XH2 vs Deye SUN-3.6K-SG01/03LP1-EU

Growatt MIN 3600TL-XH2
Growatt
MIN 3600TL-XH2
3.6 kW 97.2 % euro Hybrid
VS
Deye
SUN-3.6K-SG01/03LP1-EU
3.6 kW 96.5 % euro Hybrid
The verdict

MIN 3600TL-XH2 leads on the differences that matter

The largest is european efficiency: 0.7 pp more efficient. 8 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.

See all 17 differences
How alike are they
8 of 25 comparable
parameters are identical
identical differs not published
01

What actually differs

17 of 25 parameters
Parameter MIN 3600TL-XH2 SUN-3.6K-SG01/03LP1-EU Difference
European efficiency 97.2 % 96.5 % 0.7 pp more efficient
Max DC voltage 550 V 500 V 50 V apart
Max input current per tracker 16.0 A 11.0 A 5.0 A more headroom
Max efficiency 98.2 % 97.6 % 0.6 pp more efficient
Max AC power 3.60 kW 3.96 kW 0.36 kW apart
Max PV power 7.20 kW 4.68 kW 2.52 kW apart
DC/AC ratio 2.00 1.30 0.70 more oversizing headroom
Max charge current 17 A 120 A 103 A faster charging
Weight 10.8 kg 20.5 kg 9.7 kg lighter
Weight per kW 3.0 kg/kW 5.7 kg/kW 2.7 kg/kW lighter
Max AC current 16.0 A 18.0 A 2.0 A apart
Start voltage 50 V 150 V 100 V earlier start
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 40-540 V 125-425 V 40-540 V vs 125-425 V
Battery voltage 360-550 V 40-60 V 360-550 V vs 40-60 V
Dimensions 350x375x160 mm 580x330x232 mm 350x375x160 mm vs 580x330x232 mm
Cooling natural forced-air natural vs forced-air
02

Full specification

Parameter MIN 3600TL-XH2 SUN-3.6K-SG01/03LP1-EU Difference
AC output
Rated AC power 3.60 kW 3.60 kW Same
Max AC power 3.60 kW 3.96 kW 0.36 kW apart
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 16.0 A 18.0 A 2.0 A apart
PV input
Max PV power 7.20 kW 4.68 kW 2.52 kW apart
DC/AC ratio 2.00 1.30 +0.70 for MIN 3600TL-XH2
Max DC voltage 550 V 500 V 50 V apart
MPPT voltage range 40-540 V 125-425 V 40-540 V vs 125-425 V
Start voltage 50 V 150 V -100 V for MIN 3600TL-XH2
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 16.0 A 11.0 A +5.0 A for MIN 3600TL-XH2
Efficiency
European efficiency 97.2 % 96.5 % +0.7 pp for MIN 3600TL-XH2
Max efficiency 98.2 % 97.6 % +0.6 pp for MIN 3600TL-XH2
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 360-550 V 40-60 V 360-550 V vs 40-60 V
Max charge current 17 A 120 A +103 A for SUN-3.6K-SG01/03LP1-EU
Backup power - - Neither datasheet publishes this
Physical
Weight 10.8 kg 20.5 kg -9.7 kg for MIN 3600TL-XH2
Weight per kW 3.0 kg/kW 5.7 kg/kW -2.7 kg/kW for MIN 3600TL-XH2
Dimensions 350x375x160 mm 580x330x232 mm 350x375x160 mm vs 580x330x232 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural forced-air natural vs forced-air
Noise - 30 dB Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by Deye
Ethernet Yes - Not published by Deye
Arc fault protection Yes - Not published by Deye
Integrated DC switch Yes - Not published by Deye
Warranty
Warranty 5 yrs 5 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt MIN 3600TL-XH2 vs Growatt SPM 3600TL-HU
13 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MIN 3600TL-XH2 vs Growatt MIN 3600TL-XH
5 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Growatt MIN 3600TL-XH2 vs Growatt MIN 3600TL-XA
2 differences, the largest is warranty
04

Written summary

Checking cache...