Skip to main content
MIN 2500TL-XH2 vs MIN 2500TL-XH 24 of 29 identical Swap Change inverters

Growatt MIN 2500TL-XH2 vs Growatt MIN 2500TL-XH

Growatt MIN 2500TL-XH2
Growatt
MIN 2500TL-XH2
2.5 kW 97.1 % euro Hybrid
VS
Growatt MIN 2500TL-XH
Growatt
MIN 2500TL-XH
2.5 kW 97.1 % euro Hybrid
The verdict

MIN 2500TL-XH2 leads on the differences that matter

The largest is max input current per tracker: 2.5 A more headroom. 24 of 29 comparable parameters are identical, with 3 more left out because at least one datasheet does not publish them.

See all 5 differences
How alike are they
24 of 29 comparable
parameters are identical
identical differs not published
01

What actually differs

5 of 29 parameters
Parameter MIN 2500TL-XH2 MIN 2500TL-XH Difference
Max input current per tracker 16.0 A 13.5 A 2.5 A more headroom
Start voltage 50 V 100 V 50 V earlier start
Ingress protection IP66 IP65 IP66 vs IP65
MPPT voltage range 40-540 V 70-550 V 40-540 V vs 70-550 V
Battery voltage 360-550 V 360-550V 360-550 V vs 360-550V
02

Full specification

Parameter MIN 2500TL-XH2 MIN 2500TL-XH Difference
AC output
Rated AC power 2.50 kW 2.50 kW Same
Max AC power 2.50 kW 2.50 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 11.3 A 11.3 A Same
PV input
Max PV power 5.00 kW 5.00 kW Same
DC/AC ratio 2.00 2.00 Same
Max DC voltage 550 V 550 V Same
MPPT voltage range 40-540 V 70-550 V 40-540 V vs 70-550 V
Start voltage 50 V 100 V -50 V for MIN 2500TL-XH2
MPP trackers 2 2 Same
Strings per tracker 1 1 Same
Max input current per tracker 16.0 A 13.5 A +2.5 A for MIN 2500TL-XH2
Efficiency
European efficiency 97.1 % 97.1 % Same
Max efficiency 98.2 % 98.2 % Same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 360-550 V 360-550V 360-550 V vs 360-550V
Max charge current 17 A 17 A Same
Backup power - - Neither datasheet publishes this
Physical
Weight 10.8 kg 10.8 kg Same
Weight per kW 4.3 kg/kW 4.3 kg/kW Same
Dimensions 350x375x160 mm 350x375x160 mm Same
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs 5 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
Growatt MIN 2500TL-XH2 vs SolarEdge SE2500H
8 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MIN 2500TL-XH2 vs Growatt MIN 2500TL-XA
2 differences, the largest is warranty
Same type, similar size
Easun Power
Growatt MIN 2500TL-XH2 vs Easun Power IGrid SV LV-3K-24
9 differences, the largest is max efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.