Growatt MID 40KTL3-X2 vs Solis-40K
VS
The verdict
MID 40KTL3-X2 leads on the differences that matter
The largest is max ac power: 0.40 kW apart. 10 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
10
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 18 parameters
What actually differs
Parameter
MID 40KTL3-X2
Solis-40K
Difference
Max AC power
44.40 kW
44.00 kW
0.40 kW apart
Max PV power
60.00 kW
48.00 kW
12.00 kW apart
DC/AC ratio
1.50
1.20
0.30 more oversizing headroom
Weight
37.0 kg
61.0 kg
24.0 kg lighter
Weight per kW
0.9 kg/kW
1.5 kg/kW
0.6 kg/kW lighter
Start voltage
250 V
200 V
50 V earlier start
Ingress protection
IP66
IP65
IP66 vs IP65
Dimensions
435x580x230 mm
700x630x357 mm
435x580x230 mm vs 700x630x357 mm
02
Full specification
Parameter
MID 40KTL3-X2
Solis-40K
Difference
AC output
Rated AC power
40.00 kW
40.00 kW
Same
Max AC power
44.40 kW
44.00 kW
0.40 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
67.3 A
66.9 A
Effectively the same
PV input
Max PV power
60.00 kW
48.00 kW
12.00 kW apart
DC/AC ratio
1.50
1.20
+0.30 for MID 40KTL3-X2
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
200-1000 V
200-1000 V
Same
Start voltage
250 V
200 V
-50 V for Solis-40K
MPP trackers
-
4
Not published by Growatt
Strings per tracker
2
-
Not published by Ginlong Solis
Max input current per tracker
32.0 A
-
Not published by Ginlong Solis
Efficiency
European efficiency
-
98.4 %
Not published by Growatt
Max efficiency
98.8 %
98.8 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
37.0 kg
61.0 kg
-24.0 kg for MID 40KTL3-X2
Weight per kW
0.9 kg/kW
1.5 kg/kW
-0.6 kg/kW for MID 40KTL3-X2
Dimensions
435x580x230 mm
700x630x357 mm
435x580x230 mm vs 700x630x357 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
forced-air
-
Not published by Ginlong Solis
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
-
Not published by Ginlong Solis
Arc fault protection
Yes
-
Not published by Ginlong Solis
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MID 40KTL3-X2 vs Growatt MID 40KTL3-X
4 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Growatt MID 40KTL3-X2 vs Huawei SUN2000-40KTL-M3
7 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MID 40KTL3-X2 vs Sungrow SG40CX-P2
9 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Solis-40K vs Sungrow SG40CX
5 differences, the largest is weight
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.