Growatt MID 30KTL3-X2-1 vs SMA Solar STP 30-US-50 (Sunny Tripower X-US 30)
VS
The verdict
10 differences, and they point both ways
The largest is warranty: 5 yrs longer. 12 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
12
of 22 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 22 parameters
What actually differs
Parameter
MID 30KTL3-X2-1
STP 30-US-50 (Sunny Tripower X-US 30)
Difference
Warranty
5 yrs
10 yrs
5 yrs longer
Max DC voltage
1100 V
1000 V
100 V apart
Max input current per tracker
32.0 A
24.0 A
8.0 A more headroom
Weight
31.0 kg
35.0 kg
4.0 kg lighter
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
45.5 A
36.0 A
9.5 A apart
Ingress protection
IP66
Type 4X (UL 50E)
IP66 vs Type 4X (UL 50E)
MPPT voltage range
200-1000 V
150-1000 V
200-1000 V vs 150-1000 V
Start voltage
200 V
188 V
12 V earlier start
Dimensions
435x580x230 mm
762x728x266 mm
435x580x230 mm vs 762x728x266 mm
02
Full specification
Parameter
MID 30KTL3-X2-1
STP 30-US-50 (Sunny Tripower X-US 30)
Difference
AC output
Rated AC power
30.00 kW
30.00 kW
Same
Max AC power
30.00 kW
30.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
480 V
80 V apart
Max AC current
45.5 A
36.0 A
9.5 A apart
PV input
Max PV power
45.00 kW
45.00 kW
Same
DC/AC ratio
1.50
1.50
Same
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
200-1000 V
150-1000 V
200-1000 V vs 150-1000 V
Start voltage
200 V
188 V
-12 V for STP 30-US-50 (Sunny Tripower X-US 30)
MPP trackers
-
3
Not published by Growatt
Strings per tracker
2
2
Same
Max input current per tracker
32.0 A
24.0 A
+8.0 A for MID 30KTL3-X2-1
Efficiency
European efficiency
98.5 %
-
Not published by SMA Solar
Max efficiency
98.8 %
-
Not published by SMA Solar
CEC efficiency
-
98.0 %
Not published by Growatt
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
31.0 kg
35.0 kg
-4.0 kg for MID 30KTL3-X2-1
Weight per kW
1.0 kg/kW
1.2 kg/kW
Effectively the same
Dimensions
435x580x230 mm
762x728x266 mm
435x580x230 mm vs 762x728x266 mm
Ingress protection
IP66
Type 4X (UL 50E)
IP66 vs Type 4X (UL 50E)
Cooling
forced-air
forced-air
Same
Noise
-
59 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
-
Yes
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
10 yrs
+5 yrs for STP 30-US-50 (Sunny Tripower X-US 30)
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MID 30KTL3-X2-1 vs Growatt MID 30KTL3-X2 (Pro.E)
5 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Growatt MID 30KTL3-X2-1 vs Growatt MID 30KTL3-X
5 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Growatt MID 30KTL3-X2-1 vs GoodWe GW30K-MT
9 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.