Skip to main content
MID 30K-HU vs S6-EH3P30K-H-LV 14 of 25 identical Swap Change inverters

Growatt MID 30K-HU vs Ginlong Solis S6-EH3P30K-H-LV

Growatt MID 30K-HU
Growatt
MID 30K-HU
30 kW 97.2 % euro Hybrid
VS
Ginlong Solis S6-EH3P30K-H-LV
Ginlong Solis
S6-EH3P30K-H-LV
30 kW 95.5 % euro Hybrid
The verdict

MID 30K-HU leads on the differences that matter

The largest is european efficiency: 1.7 pp more efficient. 14 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
14 of 25 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 25 parameters
Parameter MID 30K-HU S6-EH3P30K-H-LV Difference
European efficiency 97.2 % 95.5 % 1.7 pp more efficient
Max efficiency 98.6 % 96.3 % 2.3 pp more efficient
Max charge current 42 A 140 A 98 A faster charging
Weight 48.0 kg 73.0 kg 25.0 kg lighter
Weight per kW 1.6 kg/kW 2.4 kg/kW 0.8 kg/kW lighter
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 50.0 A 78.7 A 28.7 A apart
MPPT voltage range 200-1000 V 150-850 V 200-1000 V vs 150-850 V
Start voltage 160 V 180 V 20 V earlier start
Battery voltage 600-980 V 150-800 V 600-980 V vs 150-800 V
Dimensions 570x680x256 mm 880x530x290 mm 570x680x256 mm vs 880x530x290 mm
02

Full specification

Parameter MID 30K-HU S6-EH3P30K-H-LV Difference
AC output
Rated AC power 30.00 kW 30.00 kW Same
Max AC power 30.00 kW 30.00 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 230 V 170 V apart
Max AC current 50.0 A 78.7 A 28.7 A apart
PV input
Max PV power 60.00 kW 60.00 kW Same
DC/AC ratio 2.00 2.00 Same
Max DC voltage 1000 V 1000 V Same
MPPT voltage range 200-1000 V 150-850 V 200-1000 V vs 150-850 V
Start voltage 160 V 180 V -20 V for MID 30K-HU
MPP trackers - 3 Not published by Growatt
Strings per tracker 2 2 Same
Max input current per tracker 40.0 A 40.0 A Same
Efficiency
European efficiency 97.2 % 95.5 % +1.7 pp for MID 30K-HU
Max efficiency 98.6 % 96.3 % +2.3 pp for MID 30K-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 600-980 V 150-800 V 600-980 V vs 150-800 V
Max charge current 42 A 140 A +98 A for S6-EH3P30K-H-LV
Backup power 30.0 kW 30.0 kW Same
Physical
Weight 48.0 kg 73.0 kg -25.0 kg for MID 30K-HU
Weight per kW 1.6 kg/kW 2.4 kg/kW -0.8 kg/kW for MID 30K-HU
Dimensions 570x680x256 mm 880x530x290 mm 570x680x256 mm vs 880x530x290 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise 55 dB - Not published by Ginlong Solis
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes - Not published by Ginlong Solis
Ethernet - Yes Not published by Growatt
Arc fault protection Yes - Not published by Ginlong Solis
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by Ginlong Solis
03

More useful comparisons

Open all inverters
Same type, similar size
Ginlong Solis
Growatt MID 30K-HU vs Ginlong Solis S6-EH3P30K-H
10 differences, the largest is max efficiency
Same type, similar size
Deye
Growatt MID 30K-HU vs Deye SUN-30K-SG01HP3-EU-BM3
15 differences, the largest is max input current per tracker
Same type, similar size
Growatt
Growatt MID 30K-HU vs Growatt MID 30KTL3-XH
10 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.