Growatt MID 25KTL3-X vs Deye SUN-25K-G02-LV
VS
The verdict
MID 25KTL3-X leads on the differences that matter
The largest is european efficiency: 0.6 pp more efficient. 9 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
9
of 22 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 22 parameters
What actually differs
Parameter
MID 25KTL3-X
SUN-25K-G02-LV
Difference
European efficiency
98.6 %
98.0 %
0.6 pp more efficient
Max DC voltage
1100 V
800 V
300 V apart
Max PV power
37.50 kW
32.50 kW
5.00 kW apart
MPP trackers
2
4
2 trackers more
Weight
23.0 kg
44.5 kg
21.5 kg lighter
Weight per kW
0.9 kg/kW
1.8 kg/kW
0.9 kg/kW lighter
DC/AC ratio
1.50
1.30
0.20 more oversizing headroom
Max AC power
27.70 kW
27.50 kW
0.20 kW apart
Nominal AC voltage
400 V
220 V
180 V apart
Max AC current
40.2 A
72.2 A
32.0 A apart
Max operating temperature
60 °C
65 °C
5 °C more heat tolerant
MPPT voltage range
200-1000 V
200-700 V
200-1000 V vs 200-700 V
Dimensions
395x525x222 mm
537x648x304 mm
395x525x222 mm vs 537x648x304 mm
02
Full specification
Parameter
MID 25KTL3-X
SUN-25K-G02-LV
Difference
AC output
Rated AC power
25.00 kW
25.00 kW
Same
Max AC power
27.70 kW
27.50 kW
0.20 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
220 V
180 V apart
Max AC current
40.2 A
72.2 A
32.0 A apart
PV input
Max PV power
37.50 kW
32.50 kW
5.00 kW apart
DC/AC ratio
1.50
1.30
+0.20 for MID 25KTL3-X
Max DC voltage
1100 V
800 V
300 V apart
MPPT voltage range
200-1000 V
200-700 V
200-1000 V vs 200-700 V
Start voltage
250 V
250 V
Same
MPP trackers
2
4
+2 trackers for SUN-25K-G02-LV
Strings per tracker
-
3
Not published by Growatt
Max input current per tracker
-
40.0 A
Not published by Growatt
Efficiency
European efficiency
98.6 %
98.0 %
+0.6 pp for MID 25KTL3-X
Max efficiency
98.8 %
98.7 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
23.0 kg
44.5 kg
-21.5 kg for MID 25KTL3-X
Weight per kW
0.9 kg/kW
1.8 kg/kW
-0.9 kg/kW for MID 25KTL3-X
Dimensions
395x525x222 mm
537x648x304 mm
395x525x222 mm vs 537x648x304 mm
Ingress protection
IP65
IP65
Same
Cooling
forced-air
forced-air
Same
Noise
-
45 dB
Not published by Growatt
Max operating temperature
60 °C
65 °C
+5 °C for SUN-25K-G02-LV
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
-
-
Neither datasheet publishes this
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Deye
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MID 25KTL3-X vs Growatt MID 25KTL3-X2 (Pro.E)
6 differences, the largest is start voltage
Same type, similar size
Growatt
Growatt MID 25KTL3-X vs Growatt MID 25KTL3-X1
5 differences, the largest is weight
Same type, similar size
GoodWe
Growatt MID 25KTL3-X vs GoodWe GW25K-MT
7 differences, the largest is weight
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.