Growatt MIC 3000TL-X vs Growatt MOD 3000TL3-X
VS
The verdict
15 differences, and they point both ways
The largest is max dc voltage: 550 V apart. 10 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.
See all 15 differencesHow alike are they
10
of 25 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
15 of 25 parameters
What actually differs
Parameter
MIC 3000TL-X
MOD 3000TL3-X
Difference
Max DC voltage
550 V
1100 V
550 V apart
Max efficiency
97.6 %
98.3 %
0.7 pp more efficient
European efficiency
97.1 %
97.5 %
0.4 pp more efficient
Weight
6.2 kg
12.5 kg
6.3 kg lighter
Weight per kW
2.1 kg/kW
4.2 kg/kW
2.1 kg/kW lighter
Max PV power
4.20 kW
4.50 kW
0.30 kW apart
DC/AC ratio
1.40
1.50
0.10 more oversizing headroom
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
14.3 A
5.0 A
9.3 A apart
Start voltage
50 V
160 V
110 V earlier start
MPP trackers
1
2
1 tracker more
Ingress protection
IP65
IP66
IP65 vs IP66
MPPT voltage range
50-550 V
140-1000 V
50-550 V vs 140-1000 V
Dimensions
254x274x138 mm
387x425x147 mm
254x274x138 mm vs 387x425x147 mm
02
Full specification
Parameter
MIC 3000TL-X
MOD 3000TL3-X
Difference
AC output
Rated AC power
3.00 kW
3.00 kW
Same
Max AC power
3.00 kW
3.00 kW
Same
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
230 V
400 V
170 V apart
Max AC current
14.3 A
5.0 A
9.3 A apart
PV input
Max PV power
4.20 kW
4.50 kW
0.30 kW apart
DC/AC ratio
1.40
1.50
+0.10 for MOD 3000TL3-X
Max DC voltage
550 V
1100 V
550 V apart
MPPT voltage range
50-550 V
140-1000 V
50-550 V vs 140-1000 V
Start voltage
50 V
160 V
-110 V for MIC 3000TL-X
MPP trackers
1
2
+1 trackers for MOD 3000TL3-X
Strings per tracker
1
1
Same
Max input current per tracker
13.0 A
13.0 A
Same
Efficiency
European efficiency
97.1 %
97.5 %
+0.4 pp for MOD 3000TL3-X
Max efficiency
97.6 %
98.3 %
+0.7 pp for MOD 3000TL3-X
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
6.2 kg
12.5 kg
-6.3 kg for MIC 3000TL-X
Weight per kW
2.1 kg/kW
4.2 kg/kW
-2.1 kg/kW for MIC 3000TL-X
Dimensions
254x274x138 mm
387x425x147 mm
254x274x138 mm vs 387x425x147 mm
Ingress protection
IP65
IP66
IP65 vs IP66
Cooling
natural
natural
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
Yes
Yes
Same
Arc fault protection
Yes
-
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
SolarEdge
Growatt MIC 3000TL-X vs SolarEdge SE3000H (HD‑Wave, single phase)
9 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MIC 3000TL-X vs Solis-3P3K-4G
15 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
Growatt MIC 3000TL-X vs Ginlong Solis S6-GR3P-3K02-NV-ND
15 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 3000TL3-X vs Growatt MOD 3000TL3-X2 (Pro)
5 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.