Skip to main content
MIC 2500TL-X2 vs MIN 2500TL-X 11 of 22 identical Swap Change inverters

Growatt MIC 2500TL-X2 vs Growatt MIN 2500TL-X

Growatt MIC 2500TL-X2
Growatt
MIC 2500TL-X2
2.5 kW 97.0 % euro Grid-tie
VS
Growatt MIN 2500TL-X
Growatt
MIN 2500TL-X
2.5 kW 97.1 % euro Grid-tie
The verdict

MIC 2500TL-X2 leads on the differences that matter

The largest is max input current per tracker: 2.5 A more headroom. 11 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
11 of 22 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 22 parameters
Parameter MIC 2500TL-X2 MIN 2500TL-X Difference
Max input current per tracker 16.0 A 13.5 A 2.5 A more headroom
Max efficiency 97.6 % 98.2 % 0.6 pp more efficient
Weight 6.2 kg 10.8 kg 4.6 kg lighter
Weight per kW 2.5 kg/kW 4.3 kg/kW 1.8 kg/kW lighter
Max PV power 3.75 kW 3.50 kW 0.25 kW apart
DC/AC ratio 1.50 1.40 0.10 more oversizing headroom
Start voltage 50 V 100 V 50 V earlier start
MPP trackers 1 2 1 tracker more
Ingress protection IP66 IP65 IP66 vs IP65
Max AC current 11.9 A 11.3 A 0.6 A apart
Dimensions 254x274x138 mm 350x375x160 mm 254x274x138 mm vs 350x375x160 mm
02

Full specification

Parameter MIC 2500TL-X2 MIN 2500TL-X Difference
AC output
Rated AC power 2.50 kW 2.50 kW Same
Max AC power 2.50 kW 2.50 kW Same
Grid connection Single-phase Single-phase Same
Nominal AC voltage 230 V 230 V Same
Max AC current 11.9 A 11.3 A 0.6 A apart
PV input
Max PV power 3.75 kW 3.50 kW 0.25 kW apart
DC/AC ratio 1.50 1.40 +0.10 for MIC 2500TL-X2
Max DC voltage 550 V - Not published by Growatt
MPPT voltage range 50-550 V - Not published by Growatt
Start voltage 50 V 100 V -50 V for MIC 2500TL-X2
MPP trackers 1 2 +1 trackers for MIN 2500TL-X
Strings per tracker 1 1 Same
Max input current per tracker 16.0 A 13.5 A +2.5 A for MIC 2500TL-X2
Efficiency
European efficiency 97.0 % 97.1 % Effectively the same
Max efficiency 97.6 % 98.2 % +0.6 pp for MIN 2500TL-X
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 6.2 kg 10.8 kg -4.6 kg for MIC 2500TL-X2
Weight per kW 2.5 kg/kW 4.3 kg/kW -1.8 kg/kW for MIC 2500TL-X2
Dimensions 254x274x138 mm 350x375x160 mm 254x274x138 mm vs 350x375x160 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling natural natural Same
Noise - 35 dB Not published by Growatt
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Growatt
Arc fault protection - Yes Not published by Growatt
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs 5 yrs Same
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
Growatt MIC 2500TL-X2 vs Growatt 2500-S
8 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
Growatt MIC 2500TL-X2 vs Sungrow SG2.5RS-S
7 differences, the largest is max dc voltage
Same type, similar size
GoodWe
Growatt MIC 2500TL-X2 vs GoodWe GW2500-XS
8 differences, the largest is max dc voltage
Same type, similar size
Growatt
Growatt MIN 2500TL-X vs Growatt MIC 2500TL-X
8 differences, the largest is max efficiency
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.