Skip to main content
MAX 80KTL3 LV vs SOFAR 80KTLX-G3 9 of 20 identical Swap Change inverters

Growatt MAX 80KTL3 LV vs SOFAR 80KTLX-G3

Growatt MAX 80KTL3 LV
Growatt
MAX 80KTL3 LV
80 kW 98.5 % euro Grid-tie
VS
SOFAR 80KTLX-G3
Sofar Solar
SOFAR 80KTLX-G3
80 kW 98.2 % euro Grid-tie
The verdict

SOFAR 80KTLX-G3 leads on the differences that matter

The largest is max input current per tracker: 14.0 A more headroom. 9 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.

See all 11 differences
How alike are they
9 of 20 comparable
parameters are identical
identical differs not published
01

What actually differs

11 of 20 parameters
Parameter MAX 80KTL3 LV SOFAR 80KTLX-G3 Difference
Max input current per tracker 26.0 A 40.0 A 14.0 A more headroom
Max AC power 88.80 kW 88.00 kW 0.80 kW apart
Weight 86.0 kg 50.0 kg 36.0 kg lighter
European efficiency 98.5 % 98.2 % 0.3 pp more efficient
Weight per kW 1.1 kg/kW 0.6 kg/kW 0.4 kg/kW lighter
Max efficiency 99.0 % 98.7 % 0.3 pp more efficient
Max AC current 128.8 A 133.3 A 4.5 A apart
Start voltage 250 V 200 V 50 V earlier start
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 200-1000 V 180-1000 V 200-1000 V vs 180-1000 V
Dimensions 600x860x300 mm 561x687x275 mm 600x860x300 mm vs 561x687x275 mm
02

Full specification

Parameter MAX 80KTL3 LV SOFAR 80KTLX-G3 Difference
AC output
Rated AC power 80.00 kW 80.00 kW Same
Max AC power 88.80 kW 88.00 kW 0.80 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 128.8 A 133.3 A 4.5 A apart
PV input
Max PV power 120.00 kW - Not published by Sofar Solar
DC/AC ratio 1.50 - Not published by Sofar Solar
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 200-1000 V 180-1000 V 200-1000 V vs 180-1000 V
Start voltage 250 V 200 V -50 V for SOFAR 80KTLX-G3
MPP trackers - 6 Not published by Growatt
Strings per tracker 2 2 Same
Max input current per tracker 26.0 A 40.0 A +14.0 A for SOFAR 80KTLX-G3
Efficiency
European efficiency 98.5 % 98.2 % +0.3 pp for MAX 80KTL3 LV
Max efficiency 99.0 % 98.7 % +0.3 pp for MAX 80KTL3 LV
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 86.0 kg 50.0 kg -36.0 kg for SOFAR 80KTLX-G3
Weight per kW 1.1 kg/kW 0.6 kg/kW -0.4 kg/kW for SOFAR 80KTLX-G3
Dimensions 600x860x300 mm 561x687x275 mm 600x860x300 mm vs 561x687x275 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling forced-air forced-air Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by Sofar Solar
03

More useful comparisons

Open all inverters
Same type, similar size
GoodWe
Growatt MAX 80KTL3 LV vs GoodWe GW80KBF-MT
8 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Growatt MAX 80KTL3 LV vs GoodWe GW80KHV-MT
8 differences, the largest is max input current per tracker
Same type, similar size
GoodWe
Growatt MAX 80KTL3 LV vs GoodWe GW80K-MT
10 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.