Skip to main content
MAX 50KTL3 LV vs SUN-50K-G03 9 of 21 identical Swap Change inverters

Growatt MAX 50KTL3 LV vs Deye SUN-50K-G03

Growatt MAX 50KTL3 LV
Growatt
MAX 50KTL3 LV
50 kW 98.4 % euro Grid-tie
VS
Deye SUN-50K-G03
Deye
SUN-50K-G03
50 kW 98.0 % euro Grid-tie
The verdict

SUN-50K-G03 leads on the differences that matter

The largest is max dc voltage: 100 V apart. 9 of 21 comparable parameters are identical, with 11 more left out because at least one datasheet does not publish them.

See all 12 differences
How alike are they
9 of 21 comparable
parameters are identical
identical differs not published
01

What actually differs

12 of 21 parameters
Parameter MAX 50KTL3 LV SUN-50K-G03 Difference
Max DC voltage 1100 V 1000 V 100 V apart
Max input current per tracker 26.0 A 40.0 A 14.0 A more headroom
European efficiency 98.4 % 98.0 % 0.4 pp more efficient
Max AC power 55.50 kW 55.00 kW 0.50 kW apart
Max PV power 75.00 kW 65.00 kW 10.00 kW apart
Weight 82.0 kg 44.5 kg 37.5 kg lighter
DC/AC ratio 1.50 1.30 0.20 more oversizing headroom
Weight per kW 1.6 kg/kW 0.9 kg/kW 0.7 kg/kW lighter
Max operating temperature 60 °C 65 °C 5 °C more heat tolerant
MPPT voltage range 200-1000 V 200-850 V 200-1000 V vs 200-850 V
Max AC current 80.5 A 79.7 A 0.8 A apart
Dimensions 600x860x300 mm 537x648x304 mm 600x860x300 mm vs 537x648x304 mm
02

Full specification

Parameter MAX 50KTL3 LV SUN-50K-G03 Difference
AC output
Rated AC power 50.00 kW 50.00 kW Same
Max AC power 55.50 kW 55.00 kW 0.50 kW apart
Grid connection 3-phase 3-phase Same
Nominal AC voltage 400 V 400 V Same
Max AC current 80.5 A 79.7 A 0.8 A apart
PV input
Max PV power 75.00 kW 65.00 kW 10.00 kW apart
DC/AC ratio 1.50 1.30 +0.20 for MAX 50KTL3 LV
Max DC voltage 1100 V 1000 V 100 V apart
MPPT voltage range 200-1000 V 200-850 V 200-1000 V vs 200-850 V
Start voltage 250 V 250 V Same
MPP trackers - 4 Not published by Growatt
Strings per tracker 2 - Not published by Deye
Max input current per tracker 26.0 A 40.0 A +14.0 A for SUN-50K-G03
Efficiency
European efficiency 98.4 % 98.0 % +0.4 pp for MAX 50KTL3 LV
Max efficiency 98.8 % 98.7 % Effectively the same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 82.0 kg 44.5 kg -37.5 kg for SUN-50K-G03
Weight per kW 1.6 kg/kW 0.9 kg/kW -0.7 kg/kW for SUN-50K-G03
Dimensions 600x860x300 mm 537x648x304 mm 600x860x300 mm vs 537x648x304 mm
Ingress protection IP65 IP65 Same
Cooling forced-air forced-air Same
Noise - 45 dB Not published by Growatt
Max operating temperature 60 °C 65 °C +5 °C for SUN-50K-G03
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - Yes Not published by Growatt
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty 5 yrs - Not published by Deye
03

More useful comparisons

Open all inverters
Same type, similar size
Huawei
Growatt MAX 50KTL3 LV vs Huawei SUN2000-50KTL-JPM0
8 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Growatt MAX 50KTL3 LV vs Huawei SUN2000-50KTL-M0
7 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Growatt MAX 50KTL3 LV vs Solis-50K-HV
9 differences, the largest is max ac power
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.