Growatt MAX 350K-X vs Sungrow SG350HX
VS
The verdict
SG350HX leads on the differences that matter
The largest is mpp trackers: 6 trackers more. 13 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 7 differencesHow alike are they
13
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 20 parameters
What actually differs
Parameter
MAX 350K-X
SG350HX
Difference
MPP trackers
6
12
6 trackers more
Max input current per tracker
80.0 A
40.0 A
40.0 A more headroom
Weight
126.0 kg
116.0 kg
10.0 kg lighter
European efficiency
98.5 %
98.8 %
0.3 pp more efficient
Start voltage
500 V
550 V
50 V earlier start
Strings per tracker
5
2
3 strings apart
Dimensions
790x1145x371 mm
870x1136x361 mm
790x1145x371 mm vs 870x1136x361 mm
02
Full specification
Parameter
MAX 350K-X
SG350HX
Difference
AC output
Rated AC power
350.00 kW
350.00 kW
Same
Max AC power
352.00 kW
352.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
800 V
800 V
Same
Max AC current
254.0 A
254.0 A
Same
PV input
Max PV power
528.00 kW
-
Not published by Sungrow
DC/AC ratio
1.51
-
Not published by Sungrow
Max DC voltage
1500 V
1500 V
Same
MPPT voltage range
500-1500 V
500-1500 V
Same
Start voltage
500 V
550 V
-50 V for MAX 350K-X
MPP trackers
6
12
+6 trackers for SG350HX
Strings per tracker
5
2
3 strings apart
Max input current per tracker
80.0 A
40.0 A
+40.0 A for MAX 350K-X
Efficiency
European efficiency
98.5 %
98.8 %
+0.3 pp for SG350HX
Max efficiency
99.0 %
99.0 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
126.0 kg
116.0 kg
-10.0 kg for SG350HX
Weight per kW
0.4 kg/kW
0.3 kg/kW
Effectively the same
Dimensions
790x1145x371 mm
870x1136x361 mm
790x1145x371 mm vs 870x1136x361 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Sungrow
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
-
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Sungrow
03
Open all inverters
More useful comparisons
Same type, similar size
Sofar Solar
Growatt MAX 350K-X vs SOFAR 350KTLX0
6 differences, the largest is max input current per tracker
Same type, similar size
Ginlong Solis
Growatt MAX 350K-X vs Ginlong Solis S6-GU350K-EHV-M12
6 differences, the largest is max ac power
Same type, similar size
Ginlong Solis
Growatt MAX 350K-X vs Ginlong Solis S6-GU350K-EHV-M16
6 differences, the largest is max ac power
Same type, similar size
Ginlong Solis
Sungrow SG350HX vs Ginlong Solis S6-GU3P350K06-EV-ND
9 differences, the largest is mpp trackers
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.