Growatt MAX 150KTL3-X LV vs Ginlong Solis S6-GC3P150K07-NV-ND
VS
The verdict
7 differences, and they point both ways
The largest is mpp trackers: 3 trackers more. 13 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 7 differencesHow alike are they
13
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 20 parameters
What actually differs
Parameter
MAX 150KTL3-X LV
S6-GC3P150K07-NV-ND
Difference
MPP trackers
10
7
3 trackers more
Max input current per tracker
45.0 A
54.0 A
9.0 A more headroom
Max AC power
150.00 kW
165.00 kW
15.00 kW apart
Weight
93.0 kg
105.0 kg
12.0 kg lighter
MPPT voltage range
180-1000 V
160-1000 V
180-1000 V vs 160-1000 V
Start voltage
195 V
180 V
15 V earlier start
Dimensions
640x1075x367 mm
869x1036x396 mm
640x1075x367 mm vs 869x1036x396 mm
02
Full specification
Parameter
MAX 150KTL3-X LV
S6-GC3P150K07-NV-ND
Difference
AC output
Rated AC power
150.00 kW
150.00 kW
Same
Max AC power
150.00 kW
165.00 kW
15.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
250.7 A
250.6 A
Effectively the same
PV input
Max PV power
225.00 kW
-
Not published by Ginlong Solis
DC/AC ratio
1.50
-
Not published by Ginlong Solis
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
180-1000 V
160-1000 V
180-1000 V vs 160-1000 V
Start voltage
195 V
180 V
-15 V for S6-GC3P150K07-NV-ND
MPP trackers
10
7
+3 trackers for MAX 150KTL3-X LV
Strings per tracker
-
3
Not published by Growatt
Max input current per tracker
45.0 A
54.0 A
+9.0 A for S6-GC3P150K07-NV-ND
Efficiency
European efficiency
98.4 %
98.3 %
Effectively the same
Max efficiency
98.8 %
98.8 %
Same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
93.0 kg
105.0 kg
-12.0 kg for MAX 150KTL3-X LV
Weight per kW
0.6 kg/kW
0.7 kg/kW
Effectively the same
Dimensions
640x1075x367 mm
869x1036x396 mm
640x1075x367 mm vs 869x1036x396 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
-
Yes
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Ginlong Solis
03
Open all inverters
More useful comparisons
Same type, similar size
SMA Solar
Growatt MAX 150KTL3-X LV vs SMA Solar Sunny Highpower PEAK3 SHP 150-21
11 differences, the largest is mpp trackers
Same type, similar size
SMA Solar
Growatt MAX 150KTL3-X LV vs SMA Solar Sunny Highpower Storage SHPS 150-21
7 differences, the largest is max dc voltage
Same type, similar size
Sungrow
Growatt MAX 150KTL3-X LV vs Sungrow SG150CX
7 differences, the largest is mpp trackers
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.