Growatt MAX 125KTL3-X LV vs SMA Solar STP 125-70 (Sunny Tripower 125)
VS
SMA Solar
STP 125-70 (Sunny Tripower 125)
125 kW
98.1 % euro
Grid-tie
The verdict
MAX 125KTL3-X LV leads on the differences that matter
The largest is max input current per tracker: 2.0 A more headroom. 15 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 7 differencesHow alike are they
15
of 22 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
7 of 22 parameters
What actually differs
Parameter
MAX 125KTL3-X LV
STP 125-70 (Sunny Tripower 125)
Difference
Max input current per tracker
32.0 A
30.0 A
2.0 A more headroom
MPP trackers
10
12
2 trackers more
Weight
84.0 kg
96.0 kg
12.0 kg lighter
European efficiency
98.4 %
98.1 %
0.3 pp more efficient
Max AC current
198.5 A
181.1 A
17.4 A apart
Ingress protection
IP66
IP65
IP66 vs IP65
Dimensions
640x970x345 mm
795x1020x360 mm
640x970x345 mm vs 795x1020x360 mm
02
Full specification
Parameter
MAX 125KTL3-X LV
STP 125-70 (Sunny Tripower 125)
Difference
AC output
Rated AC power
125.00 kW
125.00 kW
Same
Max AC power
125.00 kW
125.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
198.5 A
181.1 A
17.4 A apart
PV input
Max PV power
-
187.50 kW
Not published by Growatt
DC/AC ratio
-
1.50
Not published by Growatt
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
180-1000 V
180-1000 V
Same
Start voltage
195 V
200 V
Effectively the same
MPP trackers
10
12
+2 trackers for STP 125-70 (Sunny Tripower 125)
Strings per tracker
2
2
Same
Max input current per tracker
32.0 A
30.0 A
+2.0 A for MAX 125KTL3-X LV
Efficiency
European efficiency
98.4 %
98.1 %
+0.3 pp for MAX 125KTL3-X LV
Max efficiency
98.5 %
98.4 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
84.0 kg
96.0 kg
-12.0 kg for MAX 125KTL3-X LV
Weight per kW
0.7 kg/kW
0.8 kg/kW
Effectively the same
Dimensions
640x970x345 mm
795x1020x360 mm
640x970x345 mm vs 795x1020x360 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
forced-air
forced-air
Same
Noise
-
71 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
-
Yes
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Growatt MAX 125KTL3-X LV vs Ginlong Solis S5-GC125K-HV
6 differences, the largest is max ac power
Same type, similar size
Sungrow
Growatt MAX 125KTL3-X LV vs Sungrow SG125CX-P2
5 differences, the largest is max input current per tracker
Same type, similar size
Sofar Solar
Growatt MAX 125KTL3-X LV vs SOFAR 125KTLX-G4-A
4 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.
