Growatt MAX 124KTL3-X2 MV vs SolarEdge SE120KUS
VS
The verdict
SE120KUS leads on the differences that matter
The largest is rated ac power: 4.00 kW apart. 6 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.
See all 12 differencesHow alike are they
6
of 18 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
12 of 18 parameters
What actually differs
Parameter
MAX 124KTL3-X2 MV
SE120KUS
Difference
Rated AC power
124.00 kW
120.00 kW
4.00 kW apart
Max DC voltage
1100 V
1000 V
100 V apart
Max AC power
124.00 kW
120.00 kW
4.00 kW apart
Max PV power
186.00 kW
210.00 kW
24.00 kW apart
DC/AC ratio
1.50
1.75
0.25 more oversizing headroom
Weight
84.0 kg
32.0 kg
52.0 kg lighter
Weight per kW
0.7 kg/kW
0.3 kg/kW
0.4 kg/kW lighter
Nominal AC voltage
480 V
277 V
203 V apart
Max AC current
164.1 A
144.3 A
19.8 A apart
Ingress protection
IP66
NEMA 3R
IP66 vs NEMA 3R
MPPT voltage range
180-1000 V
370-1000 V
180-1000 V vs 370-1000 V
Dimensions
640x970x345 mm
558x328x273 mm
640x970x345 mm vs 558x328x273 mm
02
Full specification
Parameter
MAX 124KTL3-X2 MV
SE120KUS
Difference
AC output
Rated AC power
124.00 kW
120.00 kW
4.00 kW apart
Max AC power
124.00 kW
120.00 kW
4.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
480 V
277 V
203 V apart
Max AC current
164.1 A
144.3 A
19.8 A apart
PV input
Max PV power
186.00 kW
210.00 kW
24.00 kW apart
DC/AC ratio
1.50
1.75
+0.25 for SE120KUS
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
180-1000 V
370-1000 V
180-1000 V vs 370-1000 V
Start voltage
195 V
-
Not published by SolarEdge
MPP trackers
8
-
Not published by SolarEdge
Strings per tracker
2
-
Not published by SolarEdge
Max input current per tracker
45.0 A
-
Not published by SolarEdge
Efficiency
European efficiency
98.5 %
-
Not published by SolarEdge
Max efficiency
99.0 %
-
Not published by SolarEdge
CEC efficiency
-
98.5 %
Not published by Growatt
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
84.0 kg
32.0 kg
-52.0 kg for SE120KUS
Weight per kW
0.7 kg/kW
0.3 kg/kW
-0.4 kg/kW for SE120KUS
Dimensions
640x970x345 mm
558x328x273 mm
640x970x345 mm vs 558x328x273 mm
Ingress protection
IP66
NEMA 3R
IP66 vs NEMA 3R
Cooling
forced-air
forced-air
Same
Noise
-
67 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by SolarEdge
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Growatt MAX 124KTL3-X2 MV vs Ginlong Solis S5-GC125K-HV
8 differences, the largest is rated ac power
Same type, similar size
Growatt
Growatt MAX 124KTL3-X2 MV vs Growatt MAX 125KTL3-X LV
7 differences, the largest is rated ac power
Same type, similar size
Sungrow
Growatt MAX 124KTL3-X2 MV vs Sungrow SG125CX-P2
12 differences, the largest is rated ac power
Same type, similar size
Growatt
SolarEdge SE120KUS vs Growatt MAX 120KTL3-X LV
8 differences, the largest is max dc voltage
Same type, similar size
SolarEdge
SolarEdge SE120KUS vs SolarEdge SE120K (Synergy, 480V)
4 differences, the largest is nominal ac voltage
Same type, similar size
Growatt
SolarEdge SE120KUS vs Growatt MAX 120KTL3-X2 LV
8 differences, the largest is max dc voltage
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.