Growatt MAX 124KTL3-X2 MV vs SOFAR 125KTLX-G4-A
VS
The verdict
10 differences, and they point both ways
The largest is rated ac power: 1.00 kW apart. 12 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.
See all 10 differencesHow alike are they
12
of 22 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
10 of 22 parameters
What actually differs
Parameter
MAX 124KTL3-X2 MV
SOFAR 125KTLX-G4-A
Difference
Rated AC power
124.00 kW
125.00 kW
1.00 kW apart
Max input current per tracker
45.0 A
40.0 A
5.0 A more headroom
Max AC power
124.00 kW
125.00 kW
1.00 kW apart
MPP trackers
8
10
2 trackers more
Weight
84.0 kg
75.0 kg
9.0 kg lighter
Max efficiency
99.0 %
98.6 %
0.4 pp more efficient
European efficiency
98.5 %
98.3 %
0.2 pp more efficient
Nominal AC voltage
480 V
400 V
80 V apart
Max AC current
164.1 A
190.0 A
25.9 A apart
Dimensions
640x970x345 mm
695x970x325 mm
640x970x345 mm vs 695x970x325 mm
02
Full specification
Parameter
MAX 124KTL3-X2 MV
SOFAR 125KTLX-G4-A
Difference
AC output
Rated AC power
124.00 kW
125.00 kW
1.00 kW apart
Max AC power
124.00 kW
125.00 kW
1.00 kW apart
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
480 V
400 V
80 V apart
Max AC current
164.1 A
190.0 A
25.9 A apart
PV input
Max PV power
186.00 kW
-
Not published by Sofar Solar
DC/AC ratio
1.50
-
Not published by Sofar Solar
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
180-1000 V
180-1000 V
Same
Start voltage
195 V
200 V
Effectively the same
MPP trackers
8
10
+2 trackers for SOFAR 125KTLX-G4-A
Strings per tracker
2
2
Same
Max input current per tracker
45.0 A
40.0 A
+5.0 A for MAX 124KTL3-X2 MV
Efficiency
European efficiency
98.5 %
98.3 %
+0.2 pp for MAX 124KTL3-X2 MV
Max efficiency
99.0 %
98.6 %
+0.4 pp for MAX 124KTL3-X2 MV
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
84.0 kg
75.0 kg
-9.0 kg for SOFAR 125KTLX-G4-A
Weight per kW
0.7 kg/kW
0.6 kg/kW
Effectively the same
Dimensions
640x970x345 mm
695x970x325 mm
640x970x345 mm vs 695x970x325 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
-
Neither datasheet publishes this
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
-
Neither datasheet publishes this
Arc fault protection
Yes
Yes
Same
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by Sofar Solar
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Growatt MAX 124KTL3-X2 MV vs Ginlong Solis S5-GC125K-HV
8 differences, the largest is rated ac power
Same type, similar size
Growatt
Growatt MAX 124KTL3-X2 MV vs Growatt MAX 125KTL3-X LV
7 differences, the largest is rated ac power
Same type, similar size
Sungrow
Growatt MAX 124KTL3-X2 MV vs Sungrow SG125CX-P2
12 differences, the largest is rated ac power
Same type, similar size
Ginlong Solis
SOFAR 125KTLX-G4-A vs Ginlong Solis S6-GC125K
5 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.