Growatt MAX 120KTL3-X2 LV vs SolarEdge SE120KUS
VS
The verdict
SE120KUS leads on the differences that matter
The largest is max dc voltage: 100 V apart. 7 of 15 comparable parameters are identical, with 17 more left out because at least one datasheet does not publish them.
See all 8 differencesHow alike are they
7
of 15 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
8 of 15 parameters
What actually differs
Parameter
MAX 120KTL3-X2 LV
SE120KUS
Difference
Max DC voltage
1100 V
1000 V
100 V apart
Weight
84.0 kg
32.0 kg
52.0 kg lighter
Weight per kW
0.7 kg/kW
0.3 kg/kW
0.4 kg/kW lighter
Nominal AC voltage
400 V
277 V
123 V apart
Max AC current
190.5 A
144.3 A
46.2 A apart
Ingress protection
IP66
NEMA 3R
IP66 vs NEMA 3R
MPPT voltage range
200-1000 V
370-1000 V
200-1000 V vs 370-1000 V
Dimensions
640x970x345 mm
558x328x273 mm
640x970x345 mm vs 558x328x273 mm
02
Full specification
Parameter
MAX 120KTL3-X2 LV
SE120KUS
Difference
AC output
Rated AC power
120.00 kW
120.00 kW
Same
Max AC power
120.00 kW
120.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
277 V
123 V apart
Max AC current
190.5 A
144.3 A
46.2 A apart
PV input
Max PV power
-
210.00 kW
Not published by Growatt
DC/AC ratio
-
1.75
Not published by Growatt
Max DC voltage
1100 V
1000 V
100 V apart
MPPT voltage range
200-1000 V
370-1000 V
200-1000 V vs 370-1000 V
Start voltage
200 V
-
Not published by SolarEdge
MPP trackers
8
-
Not published by SolarEdge
Strings per tracker
2
-
Not published by SolarEdge
Max input current per tracker
45.0 A
-
Not published by SolarEdge
Efficiency
European efficiency
-
-
Neither datasheet publishes this
Max efficiency
98.7 %
-
Not published by SolarEdge
CEC efficiency
-
98.5 %
Not published by Growatt
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
84.0 kg
32.0 kg
-52.0 kg for SE120KUS
Weight per kW
0.7 kg/kW
0.3 kg/kW
-0.4 kg/kW for SE120KUS
Dimensions
640x970x345 mm
558x328x273 mm
640x970x345 mm vs 558x328x273 mm
Ingress protection
IP66
NEMA 3R
IP66 vs NEMA 3R
Cooling
forced-air
forced-air
Same
Noise
-
67 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
Yes
Same
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
-
Yes
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
-
Not published by SolarEdge
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
Growatt MAX 120KTL3-X2 LV vs Growatt MAX 120KTL3-X LV
5 differences, the largest is max input current per tracker
Same type, similar size
SolarEdge
Growatt MAX 120KTL3-X2 LV vs SolarEdge SE120K (Synergy, 480V)
9 differences, the largest is warranty
Same type, similar size
Growatt
Growatt MAX 120KTL3-X2 LV vs Growatt MAX 124KTL3-X2 MV
6 differences, the largest is rated ac power
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.