Growatt MAX 110KTL3-X LV vs SMA Solar Sunny Tripower CORE2 STP 110-60
VS

SMA Solar
Sunny Tripower CORE2 STP 110-60
110 kW
98.4 % euro
Grid-tie
The verdict
MAX 110KTL3-X LV leads on the differences that matter
The largest is max input current per tracker: 6.0 A more headroom. 14 of 20 comparable parameters are identical, with 12 more left out because at least one datasheet does not publish them.
See all 6 differencesHow alike are they
14
of 20 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
6 of 20 parameters
What actually differs
Parameter
MAX 110KTL3-X LV
Sunny Tripower CORE2 STP 110-60
Difference
Max input current per tracker
32.0 A
26.0 A
6.0 A more headroom
MPP trackers
10
12
2 trackers more
Weight
84.0 kg
93.5 kg
9.5 kg lighter
Start voltage
195 V
250 V
55 V earlier start
MPPT voltage range
180-1000 V
200-1000 V
180-1000 V vs 200-1000 V
Dimensions
640x970x345 mm
682x1117x363 mm
640x970x345 mm vs 682x1117x363 mm
02
Full specification
Parameter
MAX 110KTL3-X LV
Sunny Tripower CORE2 STP 110-60
Difference
AC output
Rated AC power
110.00 kW
110.00 kW
Same
Max AC power
110.00 kW
110.00 kW
Same
Grid connection
3-phase
3-phase
Same
Nominal AC voltage
400 V
400 V
Same
Max AC current
-
158.8 A
Not published by Growatt
PV input
Max PV power
-
165.00 kW
Not published by Growatt
DC/AC ratio
-
1.50
Not published by Growatt
Max DC voltage
1100 V
1100 V
Same
MPPT voltage range
180-1000 V
200-1000 V
180-1000 V vs 200-1000 V
Start voltage
195 V
250 V
-55 V for MAX 110KTL3-X LV
MPP trackers
10
12
+2 trackers for Sunny Tripower CORE2 STP 110-60
Strings per tracker
2
2
Same
Max input current per tracker
32.0 A
26.0 A
+6.0 A for MAX 110KTL3-X LV
Efficiency
European efficiency
98.4 %
98.4 %
Same
Max efficiency
98.5 %
98.6 %
Effectively the same
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
84.0 kg
93.5 kg
-9.5 kg for MAX 110KTL3-X LV
Weight per kW
0.8 kg/kW
0.8 kg/kW
Same
Dimensions
640x970x345 mm
682x1117x363 mm
640x970x345 mm vs 682x1117x363 mm
Ingress protection
IP66
IP66
Same
Cooling
forced-air
forced-air
Same
Noise
-
78 dB
Not published by Growatt
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by SMA Solar
Ethernet
-
Yes
Not published by Growatt
Arc fault protection
-
Yes
Not published by Growatt
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
5 yrs
5 yrs
Same
03
Open all inverters
More useful comparisons
Same type, similar size
Ginlong Solis
Growatt MAX 110KTL3-X LV vs Ginlong Solis S5-GC110K
5 differences, the largest is max ac power
Same type, similar size
Ginlong Solis
Growatt MAX 110KTL3-X LV vs Solis-110K-HV-5G
6 differences, the largest is max input current per tracker
Same type, similar size
Sofar Solar
Growatt MAX 110KTL3-X LV vs SOFAR 125KTLX-G4
4 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.