SG8.0RT-20 leads on the differences that matter
The largest is max dc voltage: 500 V apart. 6 of 19 comparable parameters are identical, with 13 more left out because at least one datasheet does not publish them.
See all 13 differencesHow alike are they
6
of 19 comparable
parameters are identical
parameters are identical
identical
differs
not published
01
13 of 19 parameters
What actually differs
Parameter
GW8K-MS-CN-G40
SG8.0RT-20
Difference
Max DC voltage
600 V
1100 V
500 V apart
Max input current per tracker
20.0 A
25.0 A
5.0 A more headroom
Max AC power
8.80 kW
8.00 kW
0.80 kW apart
Max efficiency
98.0 %
98.5 %
0.5 pp more efficient
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
220 V
400 V
180 V apart
Max AC current
40.0 A
13.3 A
26.7 A apart
Start voltage
50 V
180 V
130 V earlier start
Weight
16.0 kg
17.0 kg
1.0 kg lighter
Ingress protection
IP66
IP65
IP66 vs IP65
MPPT voltage range
40-560 V
160-1000 V
40-560 V vs 160-1000 V
Dimensions
365x493x187 mm
480x370x195 mm
365x493x187 mm vs 480x370x195 mm
Cooling
natural
forced-air
natural vs forced-air
02
Full specification
Parameter
GW8K-MS-CN-G40
SG8.0RT-20
Difference
AC output
Rated AC power
8.00 kW
8.00 kW
Same
Max AC power
8.80 kW
8.00 kW
0.80 kW apart
Grid connection
Single-phase
3-phase
Single-phase vs 3-phase
Nominal AC voltage
220 V
400 V
180 V apart
Max AC current
40.0 A
13.3 A
26.7 A apart
PV input
Max PV power
-
-
Neither datasheet publishes this
DC/AC ratio
-
-
Neither datasheet publishes this
Max DC voltage
600 V
1100 V
500 V apart
MPPT voltage range
40-560 V
160-1000 V
40-560 V vs 160-1000 V
Start voltage
50 V
180 V
-130 V for GW8K-MS-CN-G40
MPP trackers
2
2
Same
Strings per tracker
1
1
Same
Max input current per tracker
20.0 A
25.0 A
+5.0 A for SG8.0RT-20
Efficiency
European efficiency
-
98.0 %
Not published by GoodWe
Max efficiency
98.0 %
98.5 %
+0.5 pp for SG8.0RT-20
CEC efficiency
-
-
Neither datasheet publishes this
Battery
Battery input
-
-
Neither datasheet publishes this
Battery voltage
-
-
Neither datasheet publishes this
Max charge current
-
-
Neither datasheet publishes this
Backup power
-
-
Neither datasheet publishes this
Physical
Weight
16.0 kg
17.0 kg
-1.0 kg for GW8K-MS-CN-G40
Weight per kW
2.0 kg/kW
2.1 kg/kW
Effectively the same
Dimensions
365x493x187 mm
480x370x195 mm
365x493x187 mm vs 480x370x195 mm
Ingress protection
IP66
IP65
IP66 vs IP65
Cooling
natural
forced-air
natural vs forced-air
Noise
30 dB
-
Not published by Sungrow
Max operating temperature
60 °C
60 °C
Same
Connectivity and safety
Wi-Fi
Yes
-
Not published by Sungrow
Ethernet
Yes
-
Not published by Sungrow
Arc fault protection
Yes
-
Not published by Sungrow
Integrated DC switch
Yes
Yes
Same
Warranty
Warranty
-
-
Neither datasheet publishes this
03
Open all inverters
More useful comparisons
Same type, similar size
Growatt
GoodWe GW8K-MS-CN-G40 vs Growatt MOD 8000TL3-X
12 differences, the largest is max dc voltage
Same type, similar size
Growatt
GoodWe GW8K-MS-CN-G40 vs Growatt MOD 8KTL3-X2(Pro)
10 differences, the largest is max dc voltage
Same type, similar size
GoodWe
GoodWe GW8K-MS-CN-G40 vs GoodWe GW8000-DT
10 differences, the largest is max dc voltage
Same type, similar size
Ginlong Solis
Sungrow SG8.0RT-20 vs Ginlong Solis S6-GR3P-8K02-NV-ND
8 differences, the largest is max input current per tracker
04
Written summary
Checking cache...
Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.