Skip to main content
GW6000-ES-C10 vs SUN2000-6KTL-M1 8 of 24 identical Swap Change inverters

GoodWe GW6000-ES-C10 vs Huawei SUN2000-6KTL-M1

GoodWe GW6000-ES-C10
GoodWe
GW6000-ES-C10
6 kW Hybrid
VS
Huawei SUN2000-6KTL-M1
Huawei
SUN2000-6KTL-M1
6 kW 97.7 % euro Hybrid
The verdict

GW6000-ES-C10 leads on the differences that matter

The largest is max dc voltage: 500 V apart. 8 of 24 comparable parameters are identical, with 8 more left out because at least one datasheet does not publish them.

See all 16 differences
How alike are they
8 of 24 comparable
parameters are identical
identical differs not published
01

What actually differs

16 of 24 parameters
Parameter GW6000-ES-C10 SUN2000-6KTL-M1 Difference
Max DC voltage 600 V 1100 V 500 V apart
Max input current per tracker 32.0 A 11.0 A 21.0 A more headroom
Max efficiency 97.6 % 98.6 % 1.0 pp more efficient
Max PV power 12.00 kW 9.00 kW 3.00 kW apart
DC/AC ratio 2.00 1.50 0.50 more oversizing headroom
Weight 15.5 kg 17.0 kg 1.5 kg lighter
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 30.0 A 10.1 A 19.9 A apart
Start voltage 58 V 200 V 142 V earlier start
Ingress protection IP66 IP65 IP66 vs IP65
Weight per kW 2.6 kg/kW 2.8 kg/kW 0.2 kg/kW lighter
MPPT voltage range 60-550 V 140-980 V 60-550 V vs 140-980 V
Battery voltage 40~60 V 600 V ~ 980 V 40~60 V vs 600 V ~ 980 V
Dimensions 415x560x204 mm 525x470x146 mm 415x560x204 mm vs 525x470x146 mm
Cooling forced-air natural forced-air vs natural
02

Full specification

Parameter GW6000-ES-C10 SUN2000-6KTL-M1 Difference
AC output
Rated AC power 6.00 kW 6.00 kW Same
Max AC power 6.60 kW 6.60 kW Same
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 30.0 A 10.1 A 19.9 A apart
PV input
Max PV power 12.00 kW 9.00 kW 3.00 kW apart
DC/AC ratio 2.00 1.50 +0.50 for GW6000-ES-C10
Max DC voltage 600 V 1100 V 500 V apart
MPPT voltage range 60-550 V 140-980 V 60-550 V vs 140-980 V
Start voltage 58 V 200 V -142 V for GW6000-ES-C10
MPP trackers - 2 Not published by GoodWe
Strings per tracker - 1 Not published by GoodWe
Max input current per tracker 32.0 A 11.0 A +21.0 A for GW6000-ES-C10
Efficiency
European efficiency - 97.7 % Not published by GoodWe
Max efficiency 97.6 % 98.6 % +1.0 pp for SUN2000-6KTL-M1
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 40~60 V 600 V ~ 980 V 40~60 V vs 600 V ~ 980 V
Max charge current - 16 A Not published by GoodWe
Backup power - 3.3 kW Not published by GoodWe
Physical
Weight 15.5 kg 17.0 kg -1.5 kg for GW6000-ES-C10
Weight per kW 2.6 kg/kW 2.8 kg/kW -0.2 kg/kW for GW6000-ES-C10
Dimensions 415x560x204 mm 525x470x146 mm 415x560x204 mm vs 525x470x146 mm
Ingress protection IP66 IP65 IP66 vs IP65
Cooling forced-air natural forced-air vs natural
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection Yes Yes Same
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
GoodWe GW6000-ES-C10 vs SolarEdge SE6000H
9 differences, the largest is max dc voltage
Same type, similar size
Growatt
GoodWe GW6000-ES-C10 vs Growatt MOD 6000TL3-HU
13 differences, the largest is max dc voltage
Same type, similar size
Huawei
GoodWe GW6000-ES-C10 vs Huawei SUN2000-6KTL-L1
14 differences, the largest is max input current per tracker
Same type, similar size
Huawei
Huawei SUN2000-6KTL-M1 vs Huawei SUN2000-6KTL-M1 (High current version)
2 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.