Skip to main content
GW5048-EM vs MOD 5000TL3-HU 6 of 25 identical Swap Change inverters

GoodWe GW5048-EM vs Growatt MOD 5000TL3-HU

GoodWe GW5048-EM
GoodWe
GW5048-EM
5 kW 97.0 % euro Hybrid
VS
Growatt MOD 5000TL3-HU
Growatt
MOD 5000TL3-HU
5 kW 97.8 % euro Hybrid
The verdict

MOD 5000TL3-HU leads on the differences that matter

The largest is european efficiency: 0.8 pp more efficient. 6 of 25 comparable parameters are identical, with 7 more left out because at least one datasheet does not publish them.

See all 19 differences
How alike are they
6 of 25 comparable
parameters are identical
identical differs not published
01

What actually differs

19 of 25 parameters
Parameter GW5048-EM MOD 5000TL3-HU Difference
European efficiency 97.0 % 97.8 % 0.8 pp more efficient
Max DC voltage 550 V 1000 V 450 V apart
Max input current per tracker 11.0 A 20.0 A 9.0 A more headroom
Max efficiency 97.6 % 98.3 % 0.7 pp more efficient
Max AC power 5.00 kW 5.50 kW 0.50 kW apart
Max PV power 6.50 kW 10.00 kW 3.50 kW apart
DC/AC ratio 1.30 2.00 0.70 more oversizing headroom
Max charge current 50 A 25 A 25 A faster charging
Weight 17.0 kg 19.0 kg 2.0 kg lighter
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 22.8 A 8.3 A 14.5 A apart
Start voltage 125 V 180 V 55 V earlier start
Noise 25 dB 29 dB 4 dB quieter
Weight per kW 3.4 kg/kW 3.8 kg/kW 0.4 kg/kW lighter
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 100-500 V 140-1000 V 100-500 V vs 140-1000 V
Battery voltage 40-60 V 600-980 V 40-60 V vs 600-980 V
Dimensions 432x347x175 mm 468x408x202 mm 432x347x175 mm vs 468x408x202 mm
02

Full specification

Parameter GW5048-EM MOD 5000TL3-HU Difference
AC output
Rated AC power 5.00 kW 5.00 kW Same
Max AC power 5.00 kW 5.50 kW 0.50 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 22.8 A 8.3 A 14.5 A apart
PV input
Max PV power 6.50 kW 10.00 kW 3.50 kW apart
DC/AC ratio 1.30 2.00 +0.70 for MOD 5000TL3-HU
Max DC voltage 550 V 1000 V 450 V apart
MPPT voltage range 100-500 V 140-1000 V 100-500 V vs 140-1000 V
Start voltage 125 V 180 V -55 V for GW5048-EM
MPP trackers - 2 Not published by GoodWe
Strings per tracker 1 1 Same
Max input current per tracker 11.0 A 20.0 A +9.0 A for MOD 5000TL3-HU
Efficiency
European efficiency 97.0 % 97.8 % +0.8 pp for MOD 5000TL3-HU
Max efficiency 97.6 % 98.3 % +0.7 pp for MOD 5000TL3-HU
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input Yes Yes Same
Battery voltage 40-60 V 600-980 V 40-60 V vs 600-980 V
Max charge current 50 A 25 A +25 A for GW5048-EM
Backup power 2.3 kW - Not published by Growatt
Physical
Weight 17.0 kg 19.0 kg -2.0 kg for GW5048-EM
Weight per kW 3.4 kg/kW 3.8 kg/kW -0.4 kg/kW for GW5048-EM
Dimensions 432x347x175 mm 468x408x202 mm 432x347x175 mm vs 468x408x202 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise 25 dB 29 dB -4 dB for GW5048-EM
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet - - Neither datasheet publishes this
Arc fault protection - Yes Not published by GoodWe
Integrated DC switch - Yes Not published by GoodWe
Warranty
Warranty - 10 yrs Not published by GoodWe
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
GoodWe GW5048-EM vs SolarEdge StorEdge AC Coupled Single Phase Inverter (HD‑Wave) - SE5000H / H5000SE
6 differences, the largest is european efficiency
Same type, similar size
SolarEdge
GoodWe GW5048-EM vs SolarEdge SE5000H
8 differences, the largest is european efficiency
Same type, similar size
Huawei
GoodWe GW5048-EM vs Huawei SUN2000L-5KTL
11 differences, the largest is european efficiency
Same type, similar size
Huawei
Growatt MOD 5000TL3-HU vs Huawei SUN2000-5KTL-L1
16 differences, the largest is max dc voltage
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.