Skip to main content
GW33K-SDT-CN-G40 vs SG33CX 11 of 18 identical Swap Change inverters

GoodWe GW33K-SDT-CN-G40 vs Sungrow SG33CX

GoodWe GW33K-SDT-CN-G40
GoodWe
GW33K-SDT-CN-G40
33 kW Grid-tie
VS
Sungrow SG33CX
Sungrow
SG33CX
33 kW 98.3 % euro Grid-tie
The verdict

GW33K-SDT-CN-G40 leads on the differences that matter

The largest is max input current per tracker: 5.0 A more headroom. 11 of 18 comparable parameters are identical, with 14 more left out because at least one datasheet does not publish them.

See all 7 differences
How alike are they
11 of 18 comparable
parameters are identical
identical differs not published
01

What actually differs

7 of 18 parameters
Parameter GW33K-SDT-CN-G40 SG33CX Difference
Max input current per tracker 21.0 A 26.0 A 5.0 A more headroom
Weight 19.0 kg 50.0 kg 31.0 kg lighter
Weight per kW 0.6 kg/kW 1.5 kg/kW 0.9 kg/kW lighter
Nominal AC voltage 380 V 400 V 20 V apart
Start voltage 160 V 250 V 90 V earlier start
MPPT voltage range 140-1000 V 200-1000 V 140-1000 V vs 200-1000 V
Dimensions 413x530x211 mm 595x702x310 mm 413x530x211 mm vs 595x702x310 mm
02

Full specification

Parameter GW33K-SDT-CN-G40 SG33CX Difference
AC output
Rated AC power 33.00 kW 33.00 kW Same
Max AC power 36.30 kW 36.30 kW Same
Grid connection 3-phase 3-phase Same
Nominal AC voltage 380 V 400 V 20 V apart
Max AC current 55.0 A 55.2 A Effectively the same
PV input
Max PV power - - Neither datasheet publishes this
DC/AC ratio - - Neither datasheet publishes this
Max DC voltage 1100 V 1100 V Same
MPPT voltage range 140-1000 V 200-1000 V 140-1000 V vs 200-1000 V
Start voltage 160 V 250 V -90 V for GW33K-SDT-CN-G40
MPP trackers 2 - Not published by Sungrow
Strings per tracker 2 2 Same
Max input current per tracker 21.0 A 26.0 A +5.0 A for SG33CX
Efficiency
European efficiency - 98.3 % Not published by GoodWe
Max efficiency 98.7 % 98.6 % Effectively the same
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 19.0 kg 50.0 kg -31.0 kg for GW33K-SDT-CN-G40
Weight per kW 0.6 kg/kW 1.5 kg/kW -0.9 kg/kW for GW33K-SDT-CN-G40
Dimensions 413x530x211 mm 595x702x310 mm 413x530x211 mm vs 595x702x310 mm
Ingress protection IP66 IP66 Same
Cooling forced-air forced-air Same
Noise 45 dB - Not published by Sungrow
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi - - Neither datasheet publishes this
Ethernet - - Neither datasheet publishes this
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - - Neither datasheet publishes this
03

More useful comparisons

Open all inverters
Same type, similar size
Growatt
GoodWe GW33K-SDT-CN-G40 vs Growatt MID 33KTL3-X
9 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
GoodWe GW33K-SDT-CN-G40 vs Sungrow SG33T-P2-CN
8 differences, the largest is max input current per tracker
Same type, similar size
Sungrow
GoodWe GW33K-SDT-CN-G40 vs Sungrow SG33CX-P2
10 differences, the largest is max input current per tracker
Same type, similar size
Sofar Solar
Sungrow SG33CX vs SOFAR 33KTLX-G3
9 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.