Skip to main content
GW3000-XS vs MOD 3000TL3-X 7 of 22 identical Swap Change inverters

GoodWe GW3000-XS vs Growatt MOD 3000TL3-X

GoodWe GW3000-XS
GoodWe
GW3000-XS
3 kW 97.2 % euro Grid-tie
VS
Growatt MOD 3000TL3-X
Growatt
MOD 3000TL3-X
3 kW 97.5 % euro Grid-tie
The verdict

15 differences, and they point both ways

The largest is max dc voltage: 600 V apart. 7 of 22 comparable parameters are identical, with 10 more left out because at least one datasheet does not publish them.

See all 15 differences
How alike are they
7 of 22 comparable
parameters are identical
identical differs not published
01

What actually differs

15 of 22 parameters
Parameter GW3000-XS MOD 3000TL3-X Difference
Max DC voltage 500 V 1100 V 600 V apart
Max efficiency 97.6 % 98.3 % 0.7 pp more efficient
Max AC power 3.30 kW 3.00 kW 0.30 kW apart
Weight 5.8 kg 12.5 kg 6.7 kg lighter
Weight per kW 1.9 kg/kW 4.2 kg/kW 2.2 kg/kW lighter
European efficiency 97.2 % 97.5 % 0.3 pp more efficient
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 14.3 A 5.0 A 9.3 A apart
Start voltage 40 V 160 V 120 V earlier start
MPP trackers 1 2 1 tracker more
Max input current per tracker 12.5 A 13.0 A 0.5 A more headroom
Ingress protection IP65 IP66 IP65 vs IP66
MPPT voltage range 40-450 V 140-1000 V 40-450 V vs 140-1000 V
Dimensions 230x295x113 mm 387x425x147 mm 230x295x113 mm vs 387x425x147 mm
02

Full specification

Parameter GW3000-XS MOD 3000TL3-X Difference
AC output
Rated AC power 3.00 kW 3.00 kW Same
Max AC power 3.30 kW 3.00 kW 0.30 kW apart
Grid connection Single-phase 3-phase Single-phase vs 3-phase
Nominal AC voltage 230 V 400 V 170 V apart
Max AC current 14.3 A 5.0 A 9.3 A apart
PV input
Max PV power - 4.50 kW Not published by GoodWe
DC/AC ratio - 1.50 Not published by GoodWe
Max DC voltage 500 V 1100 V 600 V apart
MPPT voltage range 40-450 V 140-1000 V 40-450 V vs 140-1000 V
Start voltage 40 V 160 V -120 V for GW3000-XS
MPP trackers 1 2 +1 trackers for MOD 3000TL3-X
Strings per tracker 1 1 Same
Max input current per tracker 12.5 A 13.0 A +0.5 A for MOD 3000TL3-X
Efficiency
European efficiency 97.2 % 97.5 % +0.3 pp for MOD 3000TL3-X
Max efficiency 97.6 % 98.3 % +0.7 pp for MOD 3000TL3-X
CEC efficiency - - Neither datasheet publishes this
Battery
Battery input - - Neither datasheet publishes this
Battery voltage - - Neither datasheet publishes this
Max charge current - - Neither datasheet publishes this
Backup power - - Neither datasheet publishes this
Physical
Weight 5.8 kg 12.5 kg -6.7 kg for GW3000-XS
Weight per kW 1.9 kg/kW 4.2 kg/kW -2.2 kg/kW for GW3000-XS
Dimensions 230x295x113 mm 387x425x147 mm 230x295x113 mm vs 387x425x147 mm
Ingress protection IP65 IP66 IP65 vs IP66
Cooling natural natural Same
Noise - - Neither datasheet publishes this
Max operating temperature 60 °C 60 °C Same
Connectivity and safety
Wi-Fi Yes Yes Same
Ethernet Yes Yes Same
Arc fault protection - - Neither datasheet publishes this
Integrated DC switch Yes Yes Same
Warranty
Warranty - 5 yrs Not published by GoodWe
03

More useful comparisons

Open all inverters
Same type, similar size
SolarEdge
GoodWe GW3000-XS vs SolarEdge SE3000H (HD‑Wave, single phase)
7 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
GoodWe GW3000-XS vs Solis-3P3K-4G
12 differences, the largest is european efficiency
Same type, similar size
Ginlong Solis
GoodWe GW3000-XS vs Ginlong Solis S6-GR3P-3K02-NV-ND
14 differences, the largest is european efficiency
Same type, similar size
Growatt
Growatt MOD 3000TL3-X vs Growatt MOD 3000TL3-X2 (Pro)
5 differences, the largest is max input current per tracker
04

Written summary

Checking cache...

Every figure here is from the manufacturers' own datasheets - a dash means the value is not published, never an estimate.